Extended Encoders Configuration<br />

Sensor Types<br />

DigIN7 “High Speed Command”<br />

DigIN8 “High Speed Command”<br />

Min. differential input voltage<br />

Line receiver (internal)<br />

Max. input frequency<br />

Differential<br />

Pins [B18] / [B19]<br />

Pins [B20] / [B21]<br />

±200 mV<br />

EIA RS422 Standard<br />

5 MHz<br />

Figure 13-155<br />

<strong>EPOS2</strong> Module 36/2 – DigIN7 “Differential” Circuit (analogously valid also for DigIN8)<br />

13.3.2.3 Choice of Manufacturers for Incremental Encoder 2<br />

Manufacturer<br />

maxon<br />

Baumer<br />

Heidenhain<br />

Hengstler<br />

Scancon<br />

Contact<br />

maxon motor ag, CH-6072 Sachseln<br />

www.maxonmotor.com<br />

Baumer Electric AG, CH-8501 Frauenfeld<br />

www.baumerelectric.com<br />

DR. JOHANNES HEIDENHAIN GmbH, DE-83292 Traunreut<br />

www.heidenhain.de<br />

HENGSTLER GmbH, DE-78554 Aldingen<br />

www.hengstler.com<br />

SCANCON A/S, DK-3450 Alleroed<br />

www.scancon.dk<br />

and others<br />

Table 13-184<br />

Incremental Encoder 2 – Manufacturers (not concluding)<br />

maxon motor control<br />

<strong>EPOS2</strong> Positioning Controllers Document ID: rel3956 13-195<br />

<strong>EPOS2</strong> <strong>Application</strong> <strong>Notes</strong> <strong>Collection</strong> Edition: April 2013<br />

© 2013 maxon motor. Subject to change without prior notice.