Extended Encoders Configuration<br />

Configuration Objects<br />

13.4.5 Sinus Incremental Encoder 2 Configuration<br />

Description<br />

Used to configure the Sinus Incremental Encoder 2 Configuration’s interpretation.<br />

Remarks<br />

Can only be changed in “Disable” state.<br />

The absolute position may be corrupted after changing this parameter.<br />

Name<br />

Index<br />

Number of entries 2<br />

Sinus Incremental Encoder 2 Configuration<br />

0x2213<br />

Description<br />

Defines the resolution of “Sinus Incremental Encoder 2”. The parameter pulses per turn must be set to<br />

the number of pulses per revolution of the connected Sinus Incremental Encoder.<br />

This value multiplied by 2 number of interpolation bits is the total resolution of the Sinus Incremental Encoder.<br />

The values are further limited as follows:<br />

Max. resolution: 2 number of interpolation bits * pulses per turn ≤ 10 000 000<br />

Min. resolution: 2 number of interpolation bits * pulses per turn ≥ 64<br />

Name<br />

Sinus Incremental Encoder 2 Resolution<br />

Index<br />

0x2213<br />

Subindex<br />

0x01<br />

Type<br />

UNSIGNED32<br />

Access<br />

RW<br />

Default Value<br />

0x00800006<br />

Value Range Table 13-192<br />

Bit Name<br />

Value<br />

Minimal Maximal Default<br />

15…8 pulses per turn 1 2 500 000 2048<br />

7…0 number of interpolation bits 2 10 4<br />

Table 13-192<br />

Encoder 2 Resolution<br />

Description<br />

Position received from Sinus Incremental Encoder [Position units] (page 1-12).<br />

Name<br />

Sinus Incremental Encoder 2 Actual Position<br />

Index<br />

0x2213<br />

Subindex<br />

0x02<br />

Type<br />

INTEGER32<br />

Access<br />

RO<br />

Default Value –<br />

Value Range – –<br />

maxon motor control<br />

13-204 Document ID: rel3956 <strong>EPOS2</strong> Positioning Controllers<br />

Edition: April 2013<br />

<strong>EPOS2</strong> <strong>Application</strong> <strong>Notes</strong> <strong>Collection</strong><br />