Analog Inputs & Outputs<br />
In Brief<br />
3 Analog Inputs & Outputs<br />
3.1 In Brief<br />
Drive systems typically require inputs and outputs.<br />
The analog inputs may be used for general purpose process values (such as temperature, pressure,<br />
torque from an external sensor, etc.). Also featured are predefined functions for analog inputs (such as<br />
respective setpoints for Current Mode, Velocity Mode and Position Mode).<br />
<strong>EPOS2</strong> 50/5 additionally supports an analog output for general purposes.<br />
The inputs and outputs can easily be configured using the «Configuration Wizard» and may be changed<br />
online via CANopen or serial bus.<br />
3.1.1 Objective<br />
The present <strong>Application</strong> Note explains the functionality of analog inputs and outputs and features “in<br />
practice examples” suitable for daily use.<br />
Contents<br />
3.2 Functionality . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-44<br />
3.3 Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-47<br />
3.4 Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-54<br />
3.1.2 Scope<br />
Hardware Order # Firmware Version Reference<br />
<strong>EPOS2</strong> 2110h Firmware Specification<br />
<strong>EPOS2</strong> 70/10 375711 2120h or higher<br />
<strong>EPOS2</strong> 50/5 347717 2110h or higher<br />
Cable Starting Set<br />
Hardware Reference<br />
Cable Starting Set<br />
Hardware Reference<br />
<strong>EPOS2</strong> Module 36/2 360665 2110h or higher Hardware Reference<br />
<strong>EPOS2</strong> 24/5 367676 2110h or higher<br />
Cable Starting Set<br />
Hardware Reference<br />
<strong>EPOS2</strong> 24/2<br />
380264<br />
390003<br />
390438<br />
2121h or higher<br />
Cable Starting Set<br />
Hardware Reference<br />
Table 3-31<br />
Analog Inputs & Outputs – covered Hardware and required Documents<br />
3.1.3 Tools<br />
Tools<br />
Crimper<br />
Software<br />
Table 3-32<br />
Description<br />
Molex hand crimper (63819-0000)<br />
Molex hand crimper (63819-0900)<br />
«EPOS Studio» Version 2.00 or higher<br />
Analog Inputs & Outputs – recommended Tools<br />
maxon motor control<br />
<strong>EPOS2</strong> Positioning Controllers Document ID: rel3956 3-43<br />
<strong>EPOS2</strong> <strong>Application</strong> <strong>Notes</strong> <strong>Collection</strong> Edition: April 2013<br />