Extended Encoders Configuration<br />
Configuration Objects<br />
Value Description Abbreviation<br />
6 Incremental Encoder 2 with index (3-channel) *1)<br />
Inc Enc2<br />
7 Incremental Encoder 2 without index (2-channel) *2)<br />
8 Sinus Incremental Encoder 2 *1) Sin Inc Enc2<br />
Remarks:<br />
*1) only available with <strong>EPOS2</strong> 70/10 and <strong>EPOS2</strong> 50/5<br />
*2) only available with <strong>EPOS2</strong> 70/10, <strong>EPOS2</strong> 50/5 and <strong>EPOS2</strong> Module<br />
Table 13-188<br />
Supported Sensor Types<br />
Description<br />
Used to change the position sensor polarity.<br />
Remarks<br />
Can only be changed in “Disable” state.<br />
The absolute position may be corrupted after changing this parameter.<br />
Name<br />
Position Sensor Polarity<br />
Index<br />
0x2210<br />
Subindex<br />
0x04<br />
Type<br />
UNSIGNED16<br />
Access<br />
RW<br />
Default Value<br />
0x00<br />
Value Range Table 13-189<br />
Bit<br />
Value<br />
Name<br />
Description<br />
0<br />
1<br />
2<br />
3<br />
0 Incremental normal Enc1 polarity (CCW counts positive)<br />
1 Encoder 1 inverted Enc1 polarity (or encoder mounted on motor shaft)<br />
0<br />
normal Hall sensor polarity (maxon standard)<br />
Hall sensors<br />
1 inverted Hall sensor polarity<br />
0<br />
normal SSI polarity (CCW counts positive)<br />
SSI Encoder<br />
1 inverted SSI polarity<br />
0 Incremental normal Enc2 polarity (CCW counts positive)<br />
1 Encoder 2 *2) inverted Enc2 polarity (or encoder mounted on motor shaft)<br />
0 Sinus<br />
normal Enc2Sin Encoder polarity (CCW counts positive)<br />
4<br />
Incremental<br />
1<br />
Encoder *1) inverted Enc2Sin Encoder polarity<br />
5…15 (0) reserved –<br />
Remarks:<br />
*1) only available with <strong>EPOS2</strong> 70/10 and <strong>EPOS2</strong> 50/5<br />
*2) only available with <strong>EPOS2</strong> 70/10, <strong>EPOS2</strong> 50/5 and <strong>EPOS2</strong> Module 36/2<br />
Table 13-189<br />
Position Sensor Polarity<br />