08.10.2014 Views

Flamenco Technical Manual Revision 6.0 - Tunstall.de

Flamenco Technical Manual Revision 6.0 - Tunstall.de

Flamenco Technical Manual Revision 6.0 - Tunstall.de

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

2. Necessary previous knowledge<br />

2.5 Cables / Wiring<br />

Data cables, e.g. CAT7 (22 AWG) or commercially available communication<br />

cables IY(ST)Y... can be used for group bus OSYnet.<br />

Power supply for all components is realised with a separate net (ring system),<br />

also with commercially available cables, e.g. NYM 2x2.5 mm 2 . On average, one<br />

power supply unit is required for every 25 rooms.<br />

The room bus RAN is also realised with commercially available communication<br />

cables IY(ST)Y...<br />

Maximum cable length for the group bus OSYnet is 700 m. In exceptional circumstances,<br />

it may be exten<strong>de</strong>d for another 700 m. In this case, an OSYnet-<br />

Gateway (or<strong>de</strong>r no. 77 4001 00) is required.<br />

2.6 System limits<br />

A physical group may comprise up to 110 bus users, as there are:<br />

ComTerminal <strong>Flamenco</strong><br />

RoomTerminal <strong>Flamenco</strong><br />

ControlTerminal <strong>Flamenco</strong><br />

ControlTerminal with doorplate <strong>Flamenco</strong><br />

ComStation CT <strong>Flamenco</strong><br />

ComStation T <strong>Flamenco</strong><br />

Corridor display Alpha 16<br />

Corridor display Alpha 16, double-si<strong>de</strong>d<br />

ComStation BUS-C<br />

ComStation PC<br />

OSYlink-Door entry speaker<br />

OSYlink-Group lamp<br />

OSYlink-Universal<br />

OSYlink-Announcement<br />

OSYnet-SafetyController<br />

<strong>Flamenco</strong> - <strong>Technical</strong> <strong>Manual</strong>, 04/13 (Rev. <strong>6.0</strong>), 00 8812 60<br />