Montage D Mounting GB<br />

Anfor<strong>de</strong>rungen an <strong>de</strong>n Installationsort<br />

Bedingt zugänglicher technischer Betriebsraum<br />

Trockener Raum (Max. Luftfeuchtigkeit 75% bei ca. 18 o C)<br />

Umgebungstemperatur 0 o bis 40 o C<br />

Das OSY‐ControlCenter muss je<strong>de</strong>rzeit gut zugänglich sein (<strong>Revision</strong>sgang 60 cm<br />

breit).<br />

Freiraum für die Kabeleinführung muss berücksichtigt wer<strong>de</strong>n.<br />

Belüftung<br />

Die Wärmeabfuhr darf nicht behin<strong>de</strong>rt sein. Für eine ausreichen<strong>de</strong> Luftzirkulation über und<br />

unter <strong>de</strong>m OSY‐ControlCenter muss <strong>de</strong>shalb gesorgt wer<strong>de</strong>n. Der Abstand über und unter<br />

<strong>de</strong>m OSY‐ControlCenter zu an<strong>de</strong>ren Geräten o<strong>de</strong>r zu Wän<strong>de</strong>n muss min<strong>de</strong>stens 50 mm (im<br />

Montageschrank 3 HE) betragen. Die Lüftungsdurchlässe dürfen unter keinen Umstän<strong>de</strong>n<br />

abge<strong>de</strong>ckt sein. Beim Einbau in Schaltschränke muss gegebenenfalls durch Zwangslüftung<br />

die Verlustwärme abgeführt wer<strong>de</strong>n.<br />

Installation location requirements<br />

Limited access location for technical equipment<br />

Dry location (max. relative humidity 75% at approx. 18 o C)<br />

Ambient temperatures between 0 o and 40 o C<br />

The OSY‐ControlCenter shall be readily accessible (access aisle 60 cm wi<strong>de</strong>).<br />

Consi<strong>de</strong>r sufficient free space for cable entries.<br />

Ventilation<br />

The heat transfer must not be blocked. The selected location must ensure sufficient air<br />

circulation above and below the OSY‐ControlCenter. Therefore, check for minimum<br />

distance of 50 mm (3 U in a rack) to walls, ceiling and other equipment. The venting ports<br />

must not be covered up. Where the OSY‐ControlCenter is installed in a 19‐inch rack,<br />

forced-air ventilation may be required.<br />

Wandmontage / Wall mounting<br />

291.5<br />

Netzwerk-Schwitch<br />

network switch<br />

50<br />

Ø 12<br />

55<br />

278.9<br />

354.4<br />

Ø 7<br />

77 2000 00<br />

OSY‐ControlCenter<br />

Gewicht ohne Kabel ca. 17 kg<br />

weight without cables approx. 17 kg<br />

465,6<br />

482.6<br />

444<br />

25<br />

291.5<br />

Angaben in mm.<br />

Values in mm.<br />

<strong>Tunstall</strong> GmbH, Orkotten 66, D-48291 Telgte, www.tunstall.<strong>de</strong><br />

Einbau in 19 Zoll Montageschrank / Mounting in 19-inch rack<br />

Netzwerk-Schwitch<br />

network switch<br />

7 mm<br />

12 mm<br />

77 2000 00<br />

OSY‐ControlCenter<br />

Montagewinkel nach vorne umsetzen.<br />

Move mounting brackets to the front.<br />