6. Defining the mounting positions<br />
6.1.2 Room terminals<br />
ComTerminal <strong>Flamenco</strong><br />
Or<strong>de</strong>r no.: 77 0510 00<br />
RoomTerminal <strong>Flamenco</strong><br />
Or<strong>de</strong>r no.: 77 0520 00<br />
170 mm<br />
Location in the room:<br />
The ComTerminal <strong>Flamenco</strong> has to be installed in an acoustically<br />
convenient location, so that from all locations in the<br />
room a good speech connection over the ComTerminal<br />
<strong>Flamenco</strong> is possible.<br />
The RoomTerminal <strong>Flamenco</strong> should also be installed in an<br />
acoustically convenient location, so that a later upgrading to a<br />
Terminal with speech would be possible.<br />
1600 mm<br />
Note: If the ComTerminal <strong>Flamenco</strong> or the RoomTerminal<br />
<strong>Flamenco</strong> is not installed in the entrance area, a separate<br />
staff presence switch (70 0112 00) has to be installed near<br />
the door.<br />
2-gang back box required.<br />
Note:<br />
120 mm<br />
120 mm<br />
At 2-gang back boxes at least 120 mm space (from the<br />
centre) must be provi<strong>de</strong>d for the ComTerminal <strong>Flamenco</strong> or<br />
RoomTerminal <strong>Flamenco</strong>.<br />
44<br />