Power supply unit UPS, Or<strong>de</strong>r No. 77 3400 00<br />

6.1 Battery change<br />

Lead batteries contain harmful toxic substances. Observe general and local safety<br />

directives when during handling and transport. For disposal, comply with local directives.<br />

Pb<br />

Batteries bear the risk of excessive short-circuit currents. Never create any direct contact<br />

between the battery posts and or other conductive component parts. Therefore remove any<br />

wristband, watch, finger rings or other metal objects when working at the open power supply<br />

unit. Always use tools with standard isolating handles.<br />

Batteries may be replaced only by the same type of battery (2 x 12 V; 7 Ah). We recommend the use<br />

of the battery type BAT 24-7, <strong>Tunstall</strong> Or<strong>de</strong>r No. 00 0648 85. The use of other makes may create<br />

problems due to different connecting terminals or differing dimensions.<br />

1. Shut off mains supply to the power supply unit UPS !!!<br />

2. Release the 4 fastening screws for the left cover and remove the cover to the front.<br />

3. Confirm the position of the old battery and after its removal, install the new battery in the<br />

same manner.<br />

4. Make sure, the new battery is in the same position and check for the correct battery<br />

contacts. False connections may damage the power supply UPS !<br />

5. Check for the correct seating of the plastic cover for the batteries.<br />

6. Fix the battery position by securing it with the Velcro tape.<br />

7. Replace and close the housing.<br />

8. Perform a functional check of the power supply UPS!<br />

7. Storage<br />

If the power supply unit UPS will not be used for an exten<strong>de</strong>d period of time, the batteries must first<br />

be fully recharged to preclu<strong>de</strong> battery damage due to total discharging. (Refer to item 6 Battery<br />

service life).<br />

For the charging process, the power supply unit UPS shall be connected to the mains supply for at<br />

least 4 hours, and the UPS function shall be activated by placing the bridging contact between "x“ and<br />

"y“. After the charging process has been completed the power supply unit has to be disconnected from<br />

the mains supply and the battery fuse (un<strong>de</strong>r the left cover) has to be removed.<br />

8. Spare parts<br />

Spare part<br />

Or<strong>de</strong>r No.<br />

Rechargeable lead-gel battery, Type BAT 24-7 consisting of 2 batteries 00 0648 85<br />

Battery fuse, internal 20 A FKS 00 0132 03<br />

Mains fuse, front plate (5 x 20) T 5.0 A 00 0130 41<br />

Output fuse, bottom 15 A FKS 00 0132 02<br />

Clamp for mains connection, 3-pole 00 0211 40<br />

Clamp for 24 V connection, 4-pole 00 0211 41<br />

Clamp for control and indicator outputs, 7-pole 00 0211 39<br />

Bridging contact EB 2 – 5 for control clamps "x“ and "y“ 00 0223 56<br />