SNZ NZSr4202 75 6 8583367 0042487 Lb7 6<br />

NZS 4202: 1 995 Issued June 1995<br />

6.5 DAMP-PROOF SHEETING<br />

6.5.1<br />

Damp-proof sheetings shall be measured in square metres of surface covered. The<br />

description shall include material types, the number of layers, the width of laps and<br />

any jointing required. Where the sheeting is adhered to a surface the nature of the<br />

surface and the method of adhesion shall be described.<br />

6.5.2<br />

Turn-ups and turn-downs shall be measured in metres as extra value.<br />

6.5.3<br />

Penetrations in damp-proof sheetings shall be enumerated.<br />

6.5.4<br />

Permanent protection shall be measured in square metres.<br />

6.6 DAMP-PROOF COATINGS<br />

6.6.1<br />

Damp-proof coatings shall be measured in square metresof surface covered and the<br />

nature of the sub base stated. The description shall include material type, the number<br />

of coats and the rates of cover.<br />

6.6.2<br />

Permanent protection shall be measured in square metres.<br />

6.7 PRESTRESSED AND POST-TENSIONED WORK<br />

6.7.1 General principles<br />

6.7.1.1<br />

Prestressed work shall be scheduled separately.<br />

6.7.1.2<br />

A general description of the prestressed work and of the system and method of<br />

tensioning and jacking shall be stated.<br />

6.7.1.3<br />

The description shall include detailsof any temporary support to unitsand any testing<br />

specified.<br />

6.7.2 Measurement procedure<br />

6.7.2.1<br />

Detailed quantities shall be measured according to the appropriate sections of this<br />

Standard Method of Measurement.<br />

6.7.2.2<br />

Formation of ducts shall be measured separately in metres.<br />

6.7.2.3<br />

Forming and filling of anchorage recesses shall be enumerated.<br />

6.7.2.4<br />

Supply of tendons (measured overall between anchorages) shall be given in<br />

kilograms. Each size shall be measured separately.<br />

--`,,``,,,,,,``,``,`,,,`,,,`,-`-`,,`,,`,`,,`---<br />

6-5<br />

Copyright Standards New Zealand<br />

Provided by IHS under license with SNZ<br />

Document provided by IHS Licensee=<strong>Unitec</strong> Inst of Technology/5911177001,<br />

03/02/2005 18:31:52 MST Questions or comments about this message: please call<br />

the Document Policy Group at 303-397-2295.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!