SNZ NZS*4202 75 m 8583369 0042546 527 m<br />

Issued June 1995 NZS 4202: 1995<br />

SECTION 29 - SOLID PLASTER<br />

29.1 OVERVIEW<br />

Refer to section O, General rules, which shall be read in conjunction with this section.<br />

29.2 PREAMBLES<br />

29.2.1 Rates to include<br />

(a)<br />

(b)<br />

Temporary rules, grounds, screeds and the like;<br />

Internal angles other than coved angles:<br />

--`,,``,,,,,,``,``,`,,,`,,,`,-`-`,,`,,`,`,,`---<br />

(c)<br />

29.3 GENERAL PRINCIPLES<br />

Making good around pipes, sanitary fittings and the like.<br />

29.3.1<br />

Solid plaster shall be described and the number of coats, composition and finished<br />

thickness shall be stated. The description shall include the preparation of surfaces<br />

to be plastered, and surface finish of plaster.<br />

29.3.2<br />

Exterior work shall be scheduled separately from interior work.<br />

29.3.3<br />

Plaster shall, unless otherwise required, be scheduled in square metres of surface<br />

area covered.<br />

29.4 MEASUREMENT PROCEDURE<br />

29.4.1<br />

Plaster on concrete, blockwork, brickwork, sheet foam insulation, backing board or<br />

other surfaces shall be each measured separately.<br />

29.4.2<br />

Plaster on lathing shall be measured separately and the description shall include the<br />

lathing .<br />

29.4.3<br />

Work to floors, walls and ceilings shall be measured separately. Work to floors to falls<br />

or crossfalls shall be so described. Work to sloping ceilings shall be measured<br />

separately.<br />

29.4.4<br />

Work to integral beams, perimeter of openings and to integral columns shall be<br />

measured with the wall or ceiling and this shall be stated.<br />

29.4.5<br />

Workto isolated beams and to isolated columns shall each be measured separately.<br />

29.4.6<br />

Beams or columns where the substrate or finish are different from the abutting<br />

ceilings or walls respectively shall be measured as isolated work.<br />

Copyright Standards New Zealand<br />

Provided by IHS under license with SNZ<br />

Document provided by IHS Licensee=<strong>Unitec</strong> Inst of Technology/5911177001,<br />

03/02/2005 18:31:52 MST Questions or comments about this message: please call<br />

the Document Policy Group at 303-397-2295.<br />

29-1