NZS 4202: 1 995 Issued June 1995<br />

23.4 MEASUREMENT PROCEDURE<br />

23.4.1 Pipework<br />

23.4.1 .i<br />

Each size and specification of pipe shall be measured separately in metres, stating<br />

nominal bore and thickness or mass as required. The description shall include the<br />

type of material and method of jointing and the general background material to which<br />

the pipe is fixed.<br />

23.4.1.2<br />

Bends, elbows, tees, and the like to pipework of 25 mm nominal bore and over shall<br />

be enumerated as extra value.<br />

23.4.1.3<br />

Connections between pipes of dissimilar materials shall be enumerated.<br />

23.4.1.4<br />

Connections to existing services shall be enumerated. Meters, tobies, and the like<br />

shall be enumerated.<br />

23.4.1.5<br />

Insulation and protection to pipework shall be described and measured separately<br />

in metres for each type and size of pipe.<br />

23.4.1.6<br />

Insulation to bends, elbows, junctions, valves and the like shall be enumerated as<br />

extra value for pipework 25 mm nominal bore and over.<br />

23.4.1.7<br />

Flush pipes and sparge pipes shall be enumerated.<br />

23.4.1.8<br />

Painting and pipe identification shall be scheduled in accordance with section 35.<br />

--`,,``,,,,,,``,``,`,,,`,,,`,-`-`,,`,,`,`,,`---<br />

23.4.1.9<br />

Identification of pipework, valves and equipment shall be itemised.<br />

23.4.2 Tanks and cylinders<br />

23.4.2.1<br />

Tanks shall be enumerated. The description shall include capacity and dimensions,<br />

tappings, connections, cover, method of fixing, ballvalve, and silencing pipe.<br />

23.4.2.2<br />

Cylinders, caloriiiers, and the like shall be enumerated, and the description shall<br />

include the type, make, capacity, connections, casing and lagging. Elements,<br />

thermostats and the like, where required, shall be enumerated, and the description<br />

shall include the capacity and make.<br />

23.4.2.3<br />

Trays shall be enumerated.<br />

23.4.2.4<br />

Overflows and expansion vents shall be measured as for pipework.<br />

23-2<br />

Copyright Standards New Zealand<br />

Provided by IHS under license with SNZ<br />

Document provided by IHS Licensee=<strong>Unitec</strong> Inst of Technology/5911177001,<br />

03/02/2005 18:31:52 MST Questions or comments about this message: please call<br />

the Document Policy Group at 303-397-2295.