SNZ NZS*4202 95 m 8583Lb9 0042505 TO4 m<br />

NZS 4202:1995 Issued June 1995<br />

14.4 MEASUREMENT PROCEDURE<br />

14.4.1<br />

Deductions shall be made for sills, lintels and the like having a height of 80 mm and<br />

over, and for all openings and obstructions having an area of 0.2 m2 and over.<br />

14.4.2<br />

Cutting and fitting around all openings and obstructions of less than 0.2 m2 and<br />

cutting and fitting around pipes, standards, switches, plugs and the like shall be<br />

enumerated.<br />

14.4.3<br />

Forming of external and internal angles shall be measured separately in metres and<br />

the description shall include any special material or work involved.<br />

14.4.4<br />

Work to edges of stone shall be described and measured in metres.<br />

14.4.5<br />

Cornices, sills, skirtings, copings, treads, risers, grooves, flutings, running ornaments<br />

and the like shall be described and measured in metres. Mitres, angles, stop ends,<br />

and the like shall be enumerated.<br />

14.4.6<br />

Raking and circular cutting shall be measured in metresor included in the description<br />

of the work as appropriate.<br />

14.4.7<br />

Centring for openings shall be fully described and enumerated. Centring to be left in<br />

shall be measured separately.<br />

14.4.8<br />

Work to bench tops and the like shall be described and enumerated. The description<br />

shall include all surface finishes, edge work and fixings.<br />

14.4.9<br />

Letters, numerals, isolated enrichments and the like shall be described and<br />

enumerated.<br />

14.4.1 O<br />

Mortices, notchings and the like for fixings shall be enumerated.<br />

14.4.1 1<br />

Anchoring to structure and other fixings shall be described and enumerated.<br />

14.4.1 2<br />

Applied treatments shall be described and measured in square metres<br />

14.4.13<br />

Darnp-proof coursing shall be described and measured in metres.<br />

14.4.14<br />

Raking out of joints shall be measured in metres.<br />

14.4.15<br />

Pointing shall be described and measured in square metres.<br />

14-2<br />

--`,,``,,,,,,``,``,`,,,`,,,`,-`-`,,`,,`,`,,`---<br />

Copyright Standards New Zealand<br />

Provided by IHS under license with SNZ<br />

Document provided by IHS Licensee=<strong>Unitec</strong> Inst of Technology/5911177001,<br />

03/02/2005 18:31:52 MST Questions or comments about this message: please call<br />

the Document Policy Group at 303-397-2295.