~~ ~<br />
SNZ NZS+4202 95 W 85B3369 0042553 994<br />
NZS 4202:1995 Issued June 1995<br />
SECTION 32 -TILING<br />
32.1 OVERVIEW<br />
Refer to section O, General rules, which shall be read in conjunction with this section.<br />
32.2 PREAMBLES<br />
32.2.1 Rates to include<br />
(a)<br />
(b)<br />
Straight cutting;<br />
Protection and cleaning on completion of tiling.<br />
32.3 GENERAL PRINCIPLES<br />
32.3.1<br />
Tiling work shall be described and the type, thickness, size and shape of tiles shall<br />
be stated. The description shall include for preparation of surfaces to be tiled, the<br />
bedding or method of fixing, and the width, treatment and layout of joints.<br />
32.3.2<br />
Exterior work shall be scheduled separately from interior work.<br />
32.3.3<br />
Tiling shall, unless otherwise required, be scheduled in square metres of surface<br />
area covered.<br />
32.4 MEASUREMENT PROCEDURE<br />
32.4.1<br />
Tiling on concrete, masonry, wallboard or other surfaces shall be measured<br />
separately .<br />
32.4.2<br />
Work to floors, walls and ceilings shall be measured separately. Work to floors to falls<br />
or cross falls shall be so described. Work to sloping ceilings shall be measured<br />
separately.<br />
--`,,``,,,,,,``,``,`,,,`,,,`,-`-`,,`,,`,`,,`---<br />
32.4.3<br />
Work to integral beams, perimeter of openings and to integral columns shall be<br />
measured with the wall or ceiling and this shall be stated.<br />
32.4.4<br />
Work to isolated beams and to isolated columns shall be measured separately.<br />
32.4.5<br />
Work not exceeding 300 mm in width shall be measured in metres stating the width.<br />
This shall apply to all narrow widths except those in plane surfaces caused by<br />
openings and the like.<br />
32.4.6<br />
Deductions shall be made for all openings and obstructions having an area of 0.2 m*<br />
and over.<br />
32.4.7<br />
Work to isolated surfaces not exceeding 1 .O m2 shall be measured separately.<br />
32-1<br />