SNZ NZSx4202 95 M 8583Lb9 0042542 981 =<br />

Issued June 1995 NZS 4202: 1 995<br />

SECTION 27 - LIFTS AND ESCALATORS<br />

27.1 OVERVIEW<br />

Refer to section O, General rules, which shall be read in conjunction with this section.<br />

27.2 PREAMBLES<br />

27.2.1<br />

The type of lift or escalator, the total rise (Le., floor level at lowest level served to floor<br />

level at highest level served), number of stops, maximum capacity or loading, and<br />

the speed shall be stated.<br />

27.3 GENERAL PRINCIPLES<br />

27.3.1<br />

Builders work such as supplying and building in of plates, bolts, machine and lifting<br />

beams and the like, scaffolding to lift shafts, pit ladders and screens, unistruts etc.<br />

where not supplied by the lift sub-contractor, shall be scheduled in the appropriate<br />

section.<br />

27.3.2<br />

Building in of items normally supplied by the lift and escalator sub-contractor shall<br />

be scheduled in this section.<br />

27.4 MEASUREMENT PROCEDURE<br />

27.4.1 Lifts<br />

--`,,``,,,,,,``,``,`,,,`,,,`,-`-`,,`,,`,`,,`---<br />

27.4.1.1<br />

The dimensions, width, depth and height shall be stated. The construction of the<br />

platform and car shall be described with all internal linings and finishes stated. The<br />

provision of threshold plates, handrails, telephone cabinet, protective padded<br />

covers, doors and jambs, lighting, operating buttons and ventilation shall be stated.<br />

27.4.1.2<br />

Ropes and counterweights shall be described and enumerated.<br />

27.4.1.3<br />

Electrical work and control equipment shall be described and enumerated.<br />

27.4.1.4<br />

Motors shall be described and enumerated.<br />

27.4.1.5<br />

Hall operating buttons, indicators, faceplates, locking devices and signal fixture<br />

faceplates shall be described as to material and surface finish.<br />

27.4.1.6<br />

Doors shall be described giving size and type of construction, whether sliding, biparting,<br />

manual or automatic and surface finish stated.<br />

27.4.1.7<br />

Sills, jamb and head linings and architraves shall be described giving material<br />

sectional size and length in linear metres.<br />

Copyright Standards New Zealand<br />

Provided by IHS under license with SNZ<br />

Document provided by IHS Licensee=<strong>Unitec</strong> Inst of Technology/5911177001,<br />

03/02/2005 18:31:52 MST Questions or comments about this message: please call<br />

the Document Policy Group at 303-397-2295.<br />

27-1