25.4.8 Sundries<br />
25.4.8.1<br />
Support systems where drawn or specified to carry multiple services, access<br />
platforms and the like shall be measured separately in accordance with section 15.<br />
25.4.8.2<br />
The provision of sleeves for building in or the drilling of holes into the building<br />
structure shall be enumerated.<br />
25.4.8.3<br />
The making good, packing, sealing or fire rating of building penetrations shall be<br />
enumerated.<br />
25.4.8.4<br />
Flashing to or waterproofing of flues, pipes or ducts shall be enumerated.<br />
25.4.8.5<br />
Identification of pipework, ductwork, valves and equipment shall be itemised.<br />
25.4.9 General<br />
25.4.9.1<br />
An item shall be scheduled for obtaining all necessary approvals.<br />
25.4.9.2<br />
Provision of shop drawings, operating and maintenance manuals, as-built drawings<br />
and the like shall be itemised.<br />
25.4.9.3<br />
Testing and commissioning shall be itemised. Provision of fuel, power, lubricants,<br />
etc. shall be included in the description.<br />
25.4.9.4<br />
The provision of spares and the like shall be itemised.<br />
25.4.9.5<br />
Planned preventive maintenance, plant operation, client instruction and the like shall<br />
be itemised. If such work is to be carried out after the date for contract completion<br />
it shall be stated in the description.<br />