SNZ NZS*4202 95 m 8583Lbî 0042526 739 m<br />

Issued June 1995 NZS 4202:1995<br />

22.4.4 Accessories<br />

22.4.4.1<br />

Ridges, hips, valleys and the like shall be described and measured in metres. The<br />

description shall include the type e.g., notched, capped and the like.<br />

22.4.4.2<br />

Ridge stop ends, caps, hip starters, and the like shall be enumerated.<br />

22.4.4.3<br />

Flashings shall be measured in metres stating whether notched over roofing ribs or<br />

dressed into corrugations, etc., and the method of fixing; stepped work shall be<br />

measured separately.<br />

22.4.4.4<br />

Flashings to flues, vents and the like shall be enumerated.<br />

22.4.4.5<br />

Cutting and/or sealing of flashing chases shall be described and measured in<br />

metres.<br />

22.4.4.6<br />

Angles, mitres, stop ends, expansion joints, sumps, outlets, overflows and the like<br />

shall be enumerated.<br />

22.4.4.7<br />

Wire balloons, gratings and the like shall be enumerated. Vermin proofing, gutter<br />

guards and the like shall be measured in metres.<br />

--`,,``,,,,,,``,``,`,,,`,,,`,-`-`,,`,,`,`,,`---<br />

22.4.4.8<br />

Work about gutter and downpipe openings, pipes and the like through the roof shall<br />

be enumerated.<br />

22.4.4.9<br />

Work to dormers and the like shall be so described.<br />

22.4.5 Skylights<br />

22.4.5.1<br />

Skylights shall be enumerated and it shall be stated whether the roofing has been<br />

deducted. Flashings to skylights shall be described and included in the description<br />

with the forming of the opening in the roof.<br />

22.4.5.2<br />

Glazing to skylights shall be measured separately in accordance with section 36.<br />

22.4.6 Ventilators<br />

Roof ventilators shall be enumerated. The type of base and the size of the ventilator<br />

shall be stated.<br />

22.4.7 Gutters and downpipes<br />

Gutters, spouting, downpipes and the like where not an integral part of the roofing<br />

shall be measured in accordance with section 23.<br />

Copyright Standards New Zealand<br />

Provided by IHS under license with SNZ<br />

Document provided by IHS Licensee=<strong>Unitec</strong> Inst of Technology/5911177001,<br />

03/02/2005 18:31:52 MST Questions or comments about this message: please call<br />

the Document Policy Group at 303-397-2295.<br />

22-3