SNZ NZS*4202 95<br />

8583169 0042509 b5T M<br />

NZS 4202: 1 995 Issued June 1995<br />

SECTION 16 - METAL WINDOWS AND DOORS<br />

16.1 OVERVIEW<br />

Refer to section O, General rules, which shall be read in conjunction with this section.<br />

16.2 PREAMBLES<br />

16.2.1 Rates to include<br />

Sealants, gaskets, draught strips and the like not specifically mentioned in this<br />

section.<br />

16.3 GENERAL PRINCIPLES<br />

16.3.1<br />

Particulars shall be scheduled of the material and finish required, the material to<br />

which fixed, together with hinge systems and types.<br />

16.3.2<br />

Curtain walling, patent glazing, metal windows, doors and glazing shall be scheduled<br />

separately in this section. Metal frames not using proprietary sections may be<br />

scheduled in section 15.<br />

16.4 MEASUREMENT PROCEDURE<br />

--`,,``,,,,,,``,``,`,,,`,,,`,-`-`,,`,,`,`,,`---<br />

16.4.1<br />

Each type of window shall be enumerated separately stating the overall size and<br />

reference made to the appropriate drawings. Reveal linings shall be included in the<br />

description of the window where appropriate.<br />

16.4.2<br />

Curtain walling, patent glazing, shop fronts and the like shall be scheduled giving the<br />

quantities of the principal component parts.<br />

16.4.3<br />

Doors shall be enumerated with the frames stating the size and construction.<br />

16.4.4<br />

Structural mullions and special connecting members shall be measured separately.<br />

16.4.5<br />

Associatedflashings shall be measured in thissection in accordance with section23.<br />

16.4.6<br />

Where shop drawings and the like are required, an appropriate item shall be<br />

scheduled.<br />

16.4.7<br />

Sealants, gaskets and the like between metal sections and the structure shall be<br />

measured in metres stating the type, grade and sectional size.<br />

16.4.8<br />

Hardware shall be measured in this section in accordance with 17.4.12.<br />

16.4.9<br />

Glazing shall be measured separately in this section in accordance with section 36,<br />

except that domestic type windows may include the glazing if appropriate.<br />

16-1<br />

Copyright Standards New Zealand<br />

Provided by IHS under license with SNZ<br />

Document provided by IHS Licensee=<strong>Unitec</strong> Inst of Technology/5911177001,<br />

03/02/2005 18:31:52 MST Questions or comments about this message: please call<br />

the Document Policy Group at 303-397-2295.