WHC-SD-EN-TI-136, Rev. 0 000006<br />

All QC results were acceptable. There were no<br />

problems encountered during analysis. Solvent peaks<br />

were eliminated using electronic subtraction. Both<br />

the raw and subtracte~l chromatograms have been<br />

included in the package.<br />

4.3 EPA 8015M - PURGEABLE HYDROCARBONS:<br />

All samples were analyzed within method holding<br />

time.<br />

All QC results were acceptable. There were no<br />

problems encountered during analysis.<br />

4.4 EPA 8020 - BTEX:<br />

All samples were analyzed one day past the method<br />

holding time but within 10 days of VTSR.<br />

All QC results were #deevtable. There were no<br />

problems.<br />

All positive hits were confirmed by GCMS.<br />

5.0 DATA PACKAGE COMMENTS:<br />

The Format of the data deliverable was designed: to<br />

meet or exceed the requirements 6"f ther-Westinghouse<br />

<strong>Hanford</strong> Company Statement of Work. The intenti of<br />

the package design is'to provide sufficient data for<br />

"stand alone" validation. While the format of the<br />

package is "CLP like" Thermo Analytical Inc. makes<br />

no claim that this package duplicates in part or in<br />

total an EPA CLP data package.<br />

d<br />

I certify that this data package is in compliance with<br />

the terms and conditions of the contract, both<br />

technically and for completeness, for other than the<br />

conditions detailed above. Release of the data contained<br />

in this hard copy data package has been authorized by<br />

the Laboratory Manager or his designee, as verified by<br />

the following signature."<br />

Nicole Roth Dni .Wel<br />

CLP Manager clDrto<br />

D-138