WHC-SIY-EN-TI-1-36, Rev. 0<br />

ROY F. WESTON, INC. A Ay19<br />

Lionville Laboratory i1i RECEIVED<br />

Client: WESTINGHOUSE HANFORD<br />

RFW I 9204L881 (PETROLEUM HYDROCARBONS)<br />

W.O. #: 6168-02-01-0000 Z6%<br />

U -Indicates that the compound was analyzed for but not<br />

detected. The detection limit for the sample (not the<br />

method detection limit) is reported with U (e.g., l0u).<br />

J Indicates an estimated value. This flag is used in cases<br />

where a target analyte is detected at a level less than<br />

the lower quantification level. If the limit of<br />

quantification is l~mg/L and a concentration of 3mg/L is<br />

calculated, it is reported as 3J.<br />

NA =Not Applicable. NRl = Not Required.<br />

NC -Not calculable, results below detection limit.<br />

The method used for the analysis of petroleum hydrocarbons is EPA<br />

Method 418.1 (USEPA 600/4-79-020). Solid samples are extracted<br />

using Method 9071 (USEPA SW846) then analyzed by EPA Method 418.1.<br />

The following is a summary of the QC results accompanying these<br />

sample results and a description of any problems encountered during<br />

their analysis:<br />

* Blank was free of contamination.<br />

" Blank spike recovery was inside laboratory control<br />

limits.<br />

" Matrix spike recoveries were within laboratory control<br />

limits.<br />

Samples Received :04/03/92<br />

Date of Extraction: 04/06/92<br />

Date of Analysis :04/09/92<br />

2x)2DJ<br />

pi(. ihel Taylor -D-ae<br />

"~Project Director<br />

Lionville Analytical Laboratory<br />

D- 181