10 Linework10.1 Performing LineworkThe Survey application program is used here to explain Linework.Requirements • A display mask with a choicelist for Linework must be configured.• The flags for Linework must be defined in CONFIGURE Coding & LineworkSettings, Linework page.Accessstep-by-stepStep Description1. Select Main Menu: Survey to access SURVEY Survey Begin.2. In SURVEY Survey Begin select a job.3. Select a configuration set.4. Select an reflector.5. CONT (F1) to access SURVEY Survey: Job Name.SURVEYSurvey: Job Name,Survey pageThe most important keys are explained.ALL (F1)To measure and store distances andangles.STOP (F1)Available if and DIST (F2) was pressed. Stopsthe distance measurements. (F1)changes back to ALL.DIST (F2)To measure and display distances.Available unless and/or , after the tracking or logging isstarted.REC (F3)To record data. If and/or , records measured point andcontinues tracking.Description of fields<strong>Field</strong> Option Description User input The identifier for manually occupiedpoints. The configured point ID templateis used. The ID can be changed in thefollowing ways:Linework <strong>TPS1200</strong>+ 59