150represents flammable mixtures. For example, if 3.5% methane is present, then any coal dustconcentrations above 0.03 oz/ft 3 are flammable when mixed with the methane. If 2% methane ispresent, then any coal dust concentrations above 0.06 oz/ft 3 are flammable. This means that,if sufficient coal dust is present, an ignition can still occur at the m<strong>in</strong>e face even if the methaneconcentration is below the 5% LFL.REFERENCESCashdollar KL [1996]. Coal dust explosibility. J Loss Prev Process Ind 9(1):65–76.Cashdollar KL, Sapko MJ, Weiss ES, Hertzberg M [1987]. Laboratory and m<strong>in</strong>e dust explosionresearch at the Bureau of M<strong>in</strong>es. In: Industrial dust explosions. ASTM Special TechnicalPublication (STP) 958. West Conshohocken, PA: American Society <strong>for</strong> Test<strong>in</strong>g and Materials,pp. 107–123.CFR. Code of federal regulations. Wash<strong>in</strong>gton DC: U.S. Government Pr<strong>in</strong>t<strong>in</strong>g Office, Office ofthe Federal Register.Nagy J [1981]. The explosion hazard <strong>in</strong> m<strong>in</strong><strong>in</strong>g. Arl<strong>in</strong>gton, VA: U.S. Department of Labor,M<strong>in</strong>e Safety and Health Adm<strong>in</strong>istration, In<strong>for</strong>mational Report (IR) 1119.Nagy J, Mitchell DW, Kawenski EM [1965]. Float coal hazard <strong>in</strong> m<strong>in</strong>es: a progress report.Wash<strong>in</strong>gton, DC: U.S. Department of the Interior, Bureau of M<strong>in</strong>es, RI 6581.Rice GS, Greenwald HP [1929]. Coal dust explosibility factors <strong>in</strong>dicated by experimental m<strong>in</strong>e<strong>in</strong>vestigations, 1911 to 1929. Wash<strong>in</strong>gton, DC: U.S. Department of the Interior, Bureau ofM<strong>in</strong>es, Technical Paper (TP) 464.Rice GS, Greenwald HP, Howarth HC [1933]. Explosion tests of Pittsburgh coal dust <strong>in</strong> theexperimental m<strong>in</strong>e, 1925 to 1932 <strong>in</strong>clusive. Wash<strong>in</strong>gton, DC: U.S. Department of the Interior,Bureau of M<strong>in</strong>es, Bullet<strong>in</strong> 369.Sapko MJ, Hertzberg M, Watson RW, Cashdollar KL [1987a]. Dust explosion size scal<strong>in</strong>g. In:Proceed<strong>in</strong>gs of the Shenyang International Symposium on Dust Explosions (Shenyang, Ch<strong>in</strong>a,September 14–16, 1987).Sapko MJ, Weiss ES, Watson RW [1987b]. Explosibility of float coal dust distributed over acoal-rock dust substratum. In: Proceed<strong>in</strong>gs of the 22nd International Conference of Safety <strong>in</strong>M<strong>in</strong>es Research Institutes (Beij<strong>in</strong>g, Ch<strong>in</strong>a, November 2–6, 1987).

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!