When a dust scrubber clogs, its air quantity decl<strong>in</strong>es. Taylor et al. [1995] <strong>in</strong>vestigated ways toalert the m<strong>in</strong>er operator to a clogg<strong>in</strong>g problem. The most effective was to monitor the fan motorcurrent, s<strong>in</strong>ce an air quantity decl<strong>in</strong>e result<strong>in</strong>g from clogg<strong>in</strong>g will lower the fan motor current.• Turn<strong>in</strong>g crosscuts. Us<strong>in</strong>g a small-scale model, Tien [1989] assessed the ventilation providedby scrubbers whenever crosscuts were be<strong>in</strong>g m<strong>in</strong>ed. Results showed that keep<strong>in</strong>g the l<strong>in</strong>e curta<strong>in</strong>as close as practical to the rear of the m<strong>in</strong>er is essential <strong>for</strong> controll<strong>in</strong>g both respirable dust andmethane.• Less critical operat<strong>in</strong>g factors. Other operat<strong>in</strong>g factors, once thought to be important, haveturned out to be less critical. For example, Taylor et al. [1997] found that chang<strong>in</strong>g the l<strong>in</strong>ecurta<strong>in</strong> airflow <strong>in</strong> the range between 6,000 and 14,000 cfm does not change the average facemethane concentration. Also, methane levels do not <strong>in</strong>crease when the l<strong>in</strong>e curta<strong>in</strong> airflow is lessthan the scrubber airflow (6,000-cfm l<strong>in</strong>e curta<strong>in</strong> versus 14,000-cfm scrubber), a situation thatleads to a high amount of recirculation. Many years earlier, a study by Kissell and Bielicki[1975] led to a conclusion that recirculation per se was not harmful, as long as a sufficientquantity of fresh air was provided by the l<strong>in</strong>e curta<strong>in</strong>.45DUST SCRUBBERS WITH EXHAUST VENTILATIONDust scrubbers have also been used with exhaust ventilation. However, the major drawback tous<strong>in</strong>g scrubbers with exhaust ventilation is the need to ventilate the empty head<strong>in</strong>gs that havebeen m<strong>in</strong>ed out, but not yet bolted. The jet from a blow<strong>in</strong>g curta<strong>in</strong> can provide some m<strong>in</strong>imalventilation level, but an exhaust curta<strong>in</strong> may not [Luxner 1969].Haney et al. [1983] conducted the first tests with scrubbers and exhaust curta<strong>in</strong>, obta<strong>in</strong><strong>in</strong>g amethane dilution capacity of 33.4 cfm us<strong>in</strong>g a 6,700-cfm dust scrubber. A subsequent studyus<strong>in</strong>g a full-scale model [Taylor et al. 1996] gave methane dilution capacities rang<strong>in</strong>g from 22 to58 cfm, depend<strong>in</strong>g onairflow. 12 Both of thesestudies employed anexhaust l<strong>in</strong>e curta<strong>in</strong>located on the same sideof the entry, so the air jetfrom the scrubber feddirectly <strong>in</strong>to the l<strong>in</strong>ecurta<strong>in</strong> as shown <strong>in</strong> Figure3–10.Figure 3–10.—Dust scrubber used with exhaust ventilation.12 This study gave average methane concentrations, whereas the methane dilution capacity is normally calculatedbased on the highest measured concentration (see footnote 7). To obta<strong>in</strong> the methane dilution capacity values stated,we assumed that the highest measured concentration would be 30% greater than the average concentration.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!