Handbook for Methane Control in Mining - AMMSA

Handbook for Methane Control in Mining - AMMSA

Handbook for Methane Control in Mining - AMMSA

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

91Figure 6–12.—Underground methane pipe <strong>in</strong>stallation.4. No hoses will be used <strong>in</strong> the system, except while a hole is be<strong>in</strong>g drilled. Stress-reliev<strong>in</strong>gflexible tub<strong>in</strong>g will be used at critical po<strong>in</strong>ts, such as the head-to-pipel<strong>in</strong>e connection. This willbe sta<strong>in</strong>less steel tub<strong>in</strong>g with a triple wire braid cover.5. The steel pipel<strong>in</strong>e will be firmly supported, with no unsupported span greater than 2 ft.6. A gas water separator will be <strong>in</strong>stalled at the bottom of the vertical venthole to remove condensationthat falls back down the cas<strong>in</strong>g. Other separators will be <strong>in</strong>stalled on the holes oron the pipel<strong>in</strong>e if water production from coal warrants. All separators will preferably be commerciallymade. Water dra<strong>in</strong>s will be provided on the l<strong>in</strong>e wherever necessary.7. If steel pipel<strong>in</strong>e is used, a potential survey will be made and cathodic protection providedwhere needed.8. Automatic shut-<strong>in</strong> valves will be <strong>in</strong>stalled at each well head. These will be held open bynitrogen or air under pressure conta<strong>in</strong>ed <strong>in</strong> a fragile plastic pilot l<strong>in</strong>e runn<strong>in</strong>g parallel to andsecured on top of the pipel<strong>in</strong>e. Any roof fall or fires serious enough to damage the pipel<strong>in</strong>e willdamage the pilot l<strong>in</strong>e first and close the boreholes immediately.9. The pipel<strong>in</strong>e system will be <strong>in</strong>spected weekly by a competent person familiar with systemoperation.10. If the quantity of m<strong>in</strong>e ventilation air flow<strong>in</strong>g over the pipel<strong>in</strong>e is such that a completerupture of the pipel<strong>in</strong>e and consequent discharge of methane <strong>in</strong> m<strong>in</strong>e air will raise its concentrationabove the legal limits, a methane monitor will be used.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!