20.07.2015 Views

M16C/62 Group DATASHEET

M16C/62 Group DATASHEET

M16C/62 Group DATASHEET

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Appendix Standard Serial I/O Mode (Flash Memory Version)Mitsubishi microcomputers<strong>M16C</strong> / <strong>62</strong> <strong>Group</strong>SINGLE-CHIP 16-BIT CMOS MICROCOMPUTERPage Read CommandThis command reads the specified page (256 bytes) in the flash memory sequentially one byte at atime. Execute the page read command as explained here following.(1) Send the “FF16” command code in the 1st byte of the transmission.(2) Send addresses A8 to A15 and A16 to A23 in the 2nd and 3rd bytes of the transmission respectively.(3) From the 4th byte onward, data (D0–D7) for the page (256 bytes) specified with addresses A8 toA23 will be output sequentially from the smallest address first in sync with the rise of the clock.CLK1RxD1(<strong>M16C</strong> reception data)FF16A8 toA15A16 toA23TxD1(<strong>M16C</strong> transmit data)data0data255RTS1(BUSY)Figure 1.31.3. Timing for page readRead Status Register CommandThis command reads status information. When the “7016” command code is sent in the 1st byte of thetransmission, the contents of the status register (SRD) specified in the 2nd byte of the transmissionand the contents of status register 1 (SRD1) specified in the 3rd byte of the transmission are read.CLK1RxD1(<strong>M16C</strong> reception data)7016TxD1(<strong>M16C</strong> transmit data)SRDoutputSRD1outputRTS1(BUSY)Figure 1.31.4. Timing for reading the status register257