Table 53 Liebert NXL SA, SR, SN, MM, CD - Glossary<br />

164<br />

<strong>Modbus</strong> <strong>485</strong> <strong>and</strong> <strong>Modbus</strong> <strong>IP</strong> Protocols - UPS Systems<br />

Data Label Data Description<br />

Auto Restart In Progress Auto restart is in progress<br />

Auto Restart Inhibited - Ext Auto restart inhibited due to an external signal<br />

Automatic Restart Failed Automatic restart failed<br />

Backfeed Breaker Open The backfeed breaker is in the open position<br />

Backfeed Breaker Backfeed breaker<br />

Battery - External Monitor 1 External battery monitor 1 - battery maintenance required<br />

Battery - External Monitor 2 External battery monitor 2 - battery maintenance required<br />

Battery Amp-Hours Consumed<br />

This Discharge<br />

Battery amp-hours withdrawn this discharge.<br />

Battery Amp-Hours Consumed Cumulative battery amp-hours withdrawn over the life of the battery<br />

Battery Automatic Test Inhibited Automatic (scheduled) battery tests are inhibited<br />

Battery Capacity Low Battery capacity is low<br />

Battery Cell Count - Lead Acid Battery cell count - lead acid<br />

Battery Cell Count-Nickel<br />

Cadmium<br />

Battery cell count - nickel cadmium<br />

Battery Charging Error The battery is not charging properly<br />

Battery Charging Inhibited Battery charging is inhibited due to an external inhibit signal<br />

Battery Charging Reduced-Extrnl Using a reduced battery charging algorithm due to an external signal<br />

Battery Circuit Breaker 1 Open Battery circuit breaker 1 is open<br />

Battery Circuit Breaker 2 Open Battery circuit breaker 2 is open<br />

Battery Circuit Breaker 3 Open Battery circuit breaker 3 is open<br />

Battery Circuit Breaker 4 Open Battery circuit breaker 4 is open<br />

Battery Circuit Breaker 5 Open Battery circuit breaker 5 is open<br />

Battery Circuit Breaker 6 Open Battery circuit breaker 6 is open<br />

Battery Circuit Breaker 7 Open Battery circuit breaker 7 is open<br />

Battery Circuit Breaker 8 Open Battery circuit breaker 8 is open<br />

Battery Commission Date Date <strong>and</strong> time when battery placed into service<br />

Battery Discharge Power Instantaneous battery power while discharging<br />

Battery Discharge Time The time on battery operation for this discharge<br />

Battery Discharging The battery is discharging<br />

Battery Equalize The rectifier output voltage is increased to equalize the battery voltage level.<br />

Battery Ground Fault Battery system ground fault amperage exceeds the threshold<br />

Battery Last Discharge Date The date <strong>and</strong> time of the last battery discharge<br />

Battery Low Shutdown Battery disconnect due to end-of-discharge.<br />

Battery Low The calculated battery time remaining has reached the low battery threshold<br />

Battery Over Temperature A battery temperature sensor is reporting a value above a threshold<br />

Battery Percentage Charge The percentage of battery charge<br />

Battery Self Test Battery self test is in progress<br />

Battery Temperature for Cabinet The battery temperature for a cabinet<br />

Battery Temperature Imbalance Excessive temperature differences between battery sensors detected<br />

Battery Temperature Sensor Fault A battery temperature sensor fault has been detected<br />

Battery Test Failed Battery test failed<br />

Battery Time Remaining The calculated available time on battery<br />

Battery Total Discharge Time The cumulative battery discharge time