Table 53 Liebert NXL SA, SR, SN, MM, CD - Glossary (continued)<br />

Data Label Data Description<br />

172<br />

<strong>Modbus</strong> <strong>485</strong> <strong>and</strong> <strong>Modbus</strong> <strong>IP</strong> Protocols - UPS Systems<br />

System Status The operating status for the system<br />

System UPS Module Count Number of UPS modules in the system<br />

Time Remaining - ECO Mode Time remaining before current active ECO Mode session stops.<br />

Total kW Hours Saved Total kW hours saved by ECO Mode or Intelligent Paralleling.<br />

Total System Operating Time The cumulative operation time of the unit<br />

Trap Filter Disconnect Trap filter disconnect<br />

UPS Battery Status UPS battery status<br />

UPS Module Type UPS module type<br />

UPS Output on Bypass The output power is supplied by the bypass<br />

UPS Output Source UPS output source<br />

UPS System Output Source The UPS system's output power source<br />

Table 54 Liebert PowerSure Interactive (before July 2008) - Status <strong>and</strong> Coil<br />

Data Description Status Coil<br />

Number<br />

of Bits Scale Notes / Units<br />

Audible Alarm Enabled 10002 2 1 - -<br />

Automatic Battery Test Enabled 10003 3 1 - -<br />

Battery Charge Compensation 10046 - 1 - -<br />

Inverter Ready 10047 - 1 - -<br />

Load Circuit 1 State 10057 - 1 - -<br />

Load Circuit 2 State 10058 - 1 - -<br />

Load Circuit 3 State 10059 - 1 - -<br />

Load Circuit 4 State 10060 - 1 - -<br />

Load Circuit 5 State 10061 - 1 - -<br />

Load Circuit 6 State 10062 - 1 - -<br />

Load Circuit 7 State 10063 - 1 - -<br />

Load Circuit 8 State 10064 - 1 - -<br />

Load Circuit 9 State 10065 - 1 - -<br />

Load Circuit 10 State 10066 - 1 - -<br />

Load Circuit 11 State 10067 - 1 - -<br />

Load Circuit 12 State 10068 - 1 - -<br />

Load Circuit 13 State 10069 - 1 - -<br />

Load Circuit 14 State 10070 - 1 - -<br />

Load Circuit 15 State 10071 - 1 - -<br />

Load Circuit 16 State 10072 - 1 - -<br />

Load On Inverter 10073 - 1 - -<br />

Boost Mode On 10075 - 1 - -<br />

Buck Mode On 10076 - 1 - -<br />

Battery Under Test 10082 - 1 - -<br />

Shutdown Reason - Over Temperature 10086 - 1 - -<br />

Shutdown Reason - Overload 10087 - 1 - -<br />

Shutdown - Output Short 10089 - 1 - -<br />

Shutdown Reason - Remote Shutdown 10093 - 1 - -<br />

Load On Battery 10128 - 1 - -<br />

Output Off Pending 10151 - 1 - -