<strong>Modbus</strong> <strong>485</strong> <strong>and</strong> <strong>Modbus</strong> <strong>IP</strong> Protocols - UPS Systems<br />

Table 53 Liebert NXL<br />

MMS Module Battery Time<br />

Remaining<br />

Battery time remaining for this module in a multi-module system<br />

MMS Module DC Bus Voltage DC bus voltage of this module in a multi-module system<br />

MMS Module Inverter Status Multi-module inverter status of this module (on/off)<br />

MMS Module Number MMS module number<br />

MMS Module Output Source<br />

Module output source in a multi-module system (normal/bypass/maintenance bypass/<br />

off)<br />

MMS Module Output Voltage<br />

Status<br />

Output voltage status of this module in multi-module system<br />

MMS Module Total kVA Output Total kVA output of this module in a multi-module system<br />

MMS Module Total kW Output Total kW output of this module in a multi-module system<br />

MMS On Battery The multi-module system is on battery<br />

MMS Output Apparent Power The sum total apparent power of all system output modules<br />

MMS Output Frequency The multi-module system output frequency<br />

SA, SR, SN, MM, CD - Glossary (continued)<br />

Data Label Data Description<br />

MMS Output Pct Apparent Pwr<br />

(kVA) Phase A<br />

MMS Output Pct Apparent Pwr<br />

(kVA) Phase B<br />

MMS Output Pct Apparent Pwr<br />

(kVA) Phase C<br />

The multi-module system output apparent power on phase A as a percentage of the<br />

rated capacity<br />

The multi-module system output apparent power on phase B as a percentage of the<br />

rated capacity<br />

The multi-module system output apparent power on phase C as a percentage of the<br />

rated capacity<br />

MMS Output Pct Power Phase A<br />

The multi-module system output power on phase A as a percentage of the rated<br />

capacity<br />

MMS Output Pct Power Phase B<br />

The multi-module system output power on phase B as a percentage of the rated<br />

capacity<br />

MMS Output Pct Power Phase C<br />

The multi-module system output power on phase C as a percentage of the rated<br />

capacity<br />

MMS Output Power Factor Phase<br />

A<br />

The multi-module system output power factor for phase A<br />

MMS Output Power Factor Phase<br />

B<br />

The multi-module system output power factor for phase B<br />

MMS Output Power Factor Phase<br />

C<br />

The multi-module system output power factor for phase C<br />

MMS Output Power The sum total power of all system output modules<br />

MMS Overload Multi-module system overload<br />

MMS Power Sharing A module is not sharing power with the other modules in a multi-module system.<br />

MMS Retransfer Inhibit The critical load can not be manually retransferred from bypass to inverter<br />

MMS Transfer Inhibit The critical load can not be manually transferred from inverter to bypass<br />

MMS UPS Battery Status Multi-module UPS battery status<br />

MMS UPS Output Source Multi-module UPS output source<br />

Module In St<strong>and</strong>by - Intelligent<br />

Paralleling<br />

Module is placed into st<strong>and</strong>by operation per Intelligent Paralleling.<br />

Module Output Breaker (MOB) Module output breaker (MOB)<br />

Module Output Breaker for<br />

Module 1 (MOB1)<br />

Module output breaker for module 1 (MOB1)<br />

Module Output Breaker for<br />

Module 2 (MOB2)<br />

Module output breaker for module 2 (MOB2)<br />

Module Output Breaker for<br />

Module 3 (MOB3)<br />

Module output breaker for module 3 (MOB3)