<strong>Modbus</strong> <strong>485</strong> <strong>and</strong> <strong>Modbus</strong> <strong>IP</strong> Protocols - UPS Systems<br />

Table 53 Liebert NXL<br />

Bypass Sync Phase Difference The phase angle difference between the inverter output <strong>and</strong> bypass source<br />

Configuration Description Configuration description<br />

Continuous Operation - ECO This setting gives the user the ability to Enable/Disable ECO Mode continuous<br />

Mode<br />

operation.<br />

Controls Reset Required A controls reset is required due to one or more critical settings changing<br />

SA, SR, SN, MM, CD - Glossary (continued)<br />

Data Label Data Description<br />

DC Bus Current<br />

The current at the battery input terminals. In charging mode, the current will be a<br />

positive value. In discharging mode, the current will be a negative value<br />

DC Bus Ground Fault - Negative A ground fault has been detected on the negative DC Bus link<br />

DC Bus Ground Fault - Positive A ground fault has been detected on the positive DC Bus link<br />

DC Bus Qualification Status dc bus qualification status<br />

DC Bus Voltage<br />

The voltage between the positive <strong>and</strong> negative terminals of the DC bus at the battery<br />

input<br />

ECO Mode Active Conditions for Activation or Automatic Reactivation have been satisfied.<br />

ECO Mode Operation State This setting is used to enable or disable ECO Mode.<br />

ECO Mode Suspended ECO Mode session is suspended.<br />

Equipment Over Temperature Equipment over temperature summary event<br />

Equipment Temperature Sensor<br />

Fail<br />

One or more temperature sensors report a temperature outside of the range of<br />

expected operation.<br />

Excess ECO Suspends<br />

Number of automatic suspensions has exceeded the ECO Mode - Maximum Auto<br />

Suspensions setting.<br />

Fuse Failure A summary event indicating one or more fuse failures<br />

Inlet Air Over Temperature The inlet air exceeds the maximum temperature threshold<br />

Inlet Air Temperature The temperature of the inlet air<br />

Input Breaker (CB1/RIB) Input breaker (CB1/RIB)<br />

Input Contact 01 The external input contact 1<br />

Input Contact 02 The external input contact 2<br />

Input Contact 03 The external input contact 3<br />

Input Contact 04 The external input contact 4<br />

Input Contact 05 The external input contact 5<br />

Input Contact 06 The external input contact 6<br />

Input Contact 07 The external input contact 7<br />

Input Contact 08 The external input contact 8<br />

Input Contact 09 The external input contact 9<br />

Input Contact 10 The external input contact 10<br />

Input Contact 11 The external input contact 11<br />

Input Contact 12 The external input contact 12<br />

Input Contact 13 The external input contact 13<br />

Input Contact 14 The external input contact 14<br />

Input Contact 15 The external input contact 15<br />

Input Contact 16 The external input contact 16<br />

Input Filter Cycle Lock The input filter disconnect is open due to exceeding the maximum number of cycles.<br />

Input Isolation Transformer Input isolation transformer<br />

Input Qualification Status input qualification status<br />

Intelligent Parallel Maximum Time<br />

in St<strong>and</strong>by<br />

The maximum time a module can be in st<strong>and</strong>by mode due to Intelligent Paralleling.