date: 20–JUL–2005<br />

3. Environmental Fate and Pathways Substance ID: 71–43–2<br />

______________________________________________________________________________<br />

Flag: Risk Assessment<br />

02–SEP–2003 (436)<br />

3.6 BOD5, COD or BOD5/COD Ratio<br />

B O D 5<br />

Method: other<br />

GLP: no data<br />

BOD5: = 0 mg/l<br />

Method: other<br />

Year:<br />

GLP: no data<br />

R A T I O B O D 5 / C O D<br />

BOD5/COD: = 0<br />

Method:<br />

Result: The COD was reported to be 0.25 (no units given).<br />

Source: BP Chemicals Ltd LONDON<br />

German Rapporteur<br />

Test condition: The standard dilution technique was used with normal sewage<br />

as the seed material. No further details on the method of<br />

determining the BOD or COD values were available in the<br />

citing referencce.<br />

Reliability: (4) not assignable<br />

02–SEP–2003 (710) (1213)<br />

Method: other<br />

Year: 1971<br />

GLP: no data<br />

C O D<br />

Method: other<br />

Year: 1974<br />

GLP: no data<br />

COD: = 2150 mg/g substance<br />

R A T I O B O D 5 / C O D<br />

BOD5/COD: = 1.01<br />

Method:<br />

Result: The BOD5 was reported as 2.18 g/g (converts to 2180 mg/g).<br />

The BOD of 2180 mg/g corresponds to 71 % of theoretical<br />

oxygen demand (3080 mg/l).<br />

Source: BP Chemicals Ltd LONDON<br />

German Rapporteur<br />

Test condition: The methods of the APHA. Standard Method for the Examination<br />

of Water and Wastewater. No.219. American Public Health<br />

Association Inc., New York, (BOD Procedure), 1971 and the<br />

ASTM. Annual Book of ASTM Standards. No. D 1252–67. American<br />

Society for Testing and Materials, Philadelphia, 1974 were<br />

followed. The standard dilution method for determining BOD<br />

was conducted at 20 ± 1°C. Allyl thiourea (0.5 mg/l) was<br />

added to prevent nitrification. Filtered effluent from a<br />

biological sanitary waste treatment plant was used as seed.<br />