7 Carrier Phase Data Collection<br />

7.2.4 Time<br />

When you specify the Minimum time for which four or more satellites<br />

must be available, you are effectively setting a precision warning level<br />

below which you consider the recorded data to be insufficient.<br />

According to the precision you require, you choose a setting from the<br />

following options:<br />

10 minutes (the default)<br />

20 minutes<br />

30 minutes<br />

45 minutes<br />

For more information on configuring the Minimum time, see<br />

Configuring the Asset Surveyor Software, page 172.<br />

Counter<br />

A counter in the Asset Surveyor software starts to measure time as<br />

soon as four or more satellites are available.<br />

When the counter reaches the Minimum time specified, a ‘success<br />

beep’ sounds and a message is displayed in the status line. This<br />

indicates that the current ‘block’ contains sufficient useful data.<br />

If you lose lock before the end of the Minimum time, the data collected<br />

until then may not provide the required precision during<br />

postprocessing. Consequently, the counter is automatically reset to<br />

zero when loss of lock occurs. It only restarts when lock is regained.<br />

Note – The counter is active only if the Asset Surveyor software is<br />

logging carrier phase data from four or more satellites—it does not<br />

simply record the time that has elapsed since the beginning of the file.<br />

164 TSC1 Asset Surveyor Operation Manual

Hooray! Your file is uploaded and ready to be published.

Saved successfully!