I Laser Rangefinders<br />

3. Press the ENTER button.<br />

The following screen is displayed:<br />

DISPLAY ERRORS?<br />

**YES** NO<br />

4. Use the ← or → buttons to enable or disable the display of<br />

measurement error messages and then press ENTER.<br />

5. Press EXIT twice to return to the Criterion’s main menu.<br />

When a measurement error is detected, the Criterion displays an error<br />

code on its LCD. The meaning of each code is indicated in Table I.2.<br />

Table I.2 Error messages<br />

Message Cause and actions<br />

Error 1 The laser rangefinder failed to lock onto its target.<br />

Either the target was too close or it was out of<br />

range. Alternatively, the laser was not held<br />

steadily enough.<br />

Error 2 The laser did not receive the minimum required<br />

pulses back to determine the range to the target.<br />

Hold the instrument steady and on target.<br />

Error 3 The laser was moved off target while taking a<br />

reading. Keep the laser steady and on target.<br />

Error 4 The tilt sensor is out of range. The maximum tilt<br />

angle permitted is ±60°.<br />

Error 5 The fluxgate compass is outside its level range.<br />

When taking a compass reading, you must keep<br />

the instrument's tilt within a range of ±15°.<br />

Press the CLEAR button to clear the error message.<br />

318 TSC1 Asset Surveyor Operation Manual