7 Carrier Phase Data Collection<br />

C<br />

Feature B was unwisely recorded during a period when no useful data<br />

was recorded. You probably need to record this feature again.<br />

Feature C was started when the counter started for Block 2. Logging to<br />

this feature continued after the success beep. Then there was a loss of<br />

lock and a new block of carrier phase data started. The feature was<br />

ended before the success beep sounded for this block of data, and the<br />

file was closed. In this case, the portion of the feature collected up<br />

until the loss of lock, indicated by the end of Block 2 in Figure 7.3,<br />

should achieve the desired precision. However, the second portion of<br />

the data, associated with Block 3, may not achieve the desired<br />

precision.<br />

Warning – Only move to the next feature before the minimum time is up if<br />

loss of lock is unlikely.<br />

As you record features, be aware of the following:<br />

the number of satellites available<br />

the position of these satellites—if they are to stay visible, they<br />

should be high rather than low on the horizon<br />

any obstruction likely to cut off your view of the satellites as<br />

you move<br />

Read any messages that appear on the screen. They indicate how<br />

useful the current data is.<br />

The review screen also shows if loss of lock has occurred so you can<br />

measure that feature again if necessary. If it is clear that a block<br />

contains insufficient data, you can collect any features that are affected<br />

before leaving the site.<br />

You may sometimes decide that enough time has elapsed to provide a<br />

useful measurement, even though the specified time has not been met.<br />

This depends on the precision required.<br />

170 TSC1 Asset Surveyor Operation Manual