Laser Rangefinders I<br />

I.6.4 Configuration for Use with the Asset Surveyor Software<br />

This section provides instructions for configuring the LaserAce 300<br />

laser rangefinder itself. For more information on configuring the Asset<br />

Surveyor software to work with the LaserAce 300 laser rangefinder,<br />

see Using the LaserAce 300 with the Asset Surveyor Software,<br />

page 380.<br />

Calibration of the LaserAce 300<br />

Whenever you use the LaserAce 300 after storing it for a period, or in<br />

a new environment, calibrate the LaserAce 300’s compass. This is<br />

particularly important if you feel that the site in which you are<br />

working is hostile in the sense of there being local magnetic field<br />

distortions (for example, a vehicle, pipeline, or overhead or<br />

underground power cable). The purpose of calibration is to distribute<br />

compass error smoothly through a 360° circle.<br />

Note – The calibration procedure does not modify the compass’s idea<br />

of where magnetic north is. It simply distributes local distortion of the<br />

earth’s magnetic field evenly through a 360° circle. This is important<br />

as it ensures that compass readings are locally consistent. If you want<br />

to account for an error in the compass’s determination of magnetic<br />

north, do this by entering a new value for the Magnetic declination<br />

field in the Asset Surveyor software’s Units and display configuration<br />

form.<br />

Calibration of the compass is quick and simple. Follow the<br />

instructions below:<br />

1. Press the FIRE button to turn on the LaserAce.<br />

2. Press the button until the display shows Mode 3.<br />

3. Press the FIRE button.<br />

When the compass is ready for calibration, the display prompts<br />

you to point the LaserAce 300 in a sequence of directions<br />

starting at 0° (due North).<br />