(8)<br />

(10)<br />

(12) B<br />

(6)<br />

(4)<br />

(2)<br />

A<br />

C<br />

D<br />

Figue.4 Cable net layout<br />

Table.2 the initial pre-stress of the cable nets<br />

Location<br />

RIC<br />

1 2 3 4 5 6<br />

Pre- stress( 103kN ) 51.05~54.60 21.57~22.65 19.64~20.83 17.42~18.39 17.30~18.16 16.89~17.61<br />

RIC<br />

Location<br />

RAC<br />

7 8 9 10<br />

Pre- stress( 103kN ) 16.15~16.72 15.04~15.49 14.91~15.29 14.59~14.91 5.91~26.64<br />

Deflexion (m)<br />

0.40<br />

0.35<br />

0.30<br />

0.25<br />

0.20<br />

0.15<br />

0.10<br />

0.05<br />

0.00<br />

Load step<br />

1<br />

2<br />

3<br />

4<br />

5<br />

Link A<br />

1 2 3 4 5 6 7 8 9 10 11<br />

Node<br />

Figure.5 Deflection of cable nets<br />

Tension (kN)<br />

51110<br />

51100<br />

1<br />

51090<br />

51080<br />

51070<br />

51060<br />

51050<br />

1/5 2/5 3/5 4/5 1<br />

Load Step<br />

Figure.6 Tension of cable nets<br />

In the case of uniform loading condition as dead load plus snow, 0.55kN/m2, and nonlinear static analysis was<br />

carried out with load increment of five steps. Figure.5 shows the deflection of cable link-A. <strong>The</strong> maximum is<br />

about 0.4m, less 1/250 cover span, and the deflection increase approximated to linear with load add, but increase<br />

fairly small from outer to opening unlike cantilever behaviour. Figure.6 shows the inner ring cable tension with<br />

respect to loading, which increase un-strong nonlinearly.<br />

WIND-INDUCED DYNAMIC PERFORMANCE<br />

<strong>The</strong> light structure is proved sensitive to wind action. <strong>The</strong> basic dynamic structural performance needs<br />

evaluating in structural design. <strong>The</strong> static nonlinear analysis results indicated the pre-stressed cable net does not<br />

behaviour strong nonlinearly. <strong>The</strong> frequency domain method was employed to calculate the response. <strong>The</strong><br />

modal analysis was thus performed firstly.<br />

-454-