APPENDIX C<br />

basis and at a frequency of at least 1 per every 20 samples. The RPD between duplicates or<br />

matrix spike duplicates measures the precision of a given analysis. RPDs are calculated as<br />

follows:<br />

%RPD =<br />

%RPD =<br />

R - R<br />

S<br />

1<br />

R<br />

or<br />

1<br />

S<br />

av<br />

- S<br />

av<br />

2<br />

2<br />

x 100<br />

x 100<br />

where,<br />

R 1 and R 2 = duplicate determinations of the analyte in the sample<br />

S 1 and S 2 = the observed concentrations of analyte in the spike and its duplicate<br />

R av<br />

S av<br />

= (R1+R2)/2<br />

= (S1+S2)/2<br />

Laboratory Control Sample (LCS)/Laboratory Control Sample Duplicate (LCSD)—<br />

Laboratory control standards are aliquots of organic-free or deionized water to which known<br />

amounts of analyte have been added for water matrices. Other reference materials may be<br />

used for other matrices. They are subjected to the sample preparation or extraction<br />

procedure and analyzed as samples. The stock solutions used for LCSs are purchased or<br />

prepared independently of calibration standards. The LCS recovery tests the function of<br />

analytical methods and equipment. LCS/LCSDs are prepared and analyzed on a daily basis<br />

or at a frequency of 1 per 20 samples. Laboratory control limits are calculated when 20 data<br />

points become available.<br />

In addition to the aforementioned QC samples, the following QC parameters are utilized as part of the<br />

QA/QC program for environmental samples collected at Kirtland AFB:<br />

Holding Times—Holding time compliance (see Table 5-1) is carefully monitored through<br />

internal laboratory procedures.<br />

ICP Interference Check Samples—These samples are run, as necessary, as a check on interelemental<br />

interferences during ICP analyses.<br />

Single Spike Analysis for Metals Analyzed by Furnace—Each sample is run as a postdigestion<br />

spike. Where matrix interference is indicated, the sample is run by Method of<br />

Standard Additions (MSA).<br />

ICP Internal Standardization—Internal standardization is an acceptable substitute for MSA<br />

in ICP analyses, and may be used by the analytical laboratory.<br />

ICP Linear Ranges—Are evaluated on a quarterly basis and will be reported by the<br />

analytical laboratory.<br />

Kirtland AFB<br />

Quality Assurance Project Plan C-45 April 2004