24.04.2015 Views

KIRTLAND AIR FORCE BASE ALBUQUERQUE, NEW MEXICO ...

KIRTLAND AIR FORCE BASE ALBUQUERQUE, NEW MEXICO ...

KIRTLAND AIR FORCE BASE ALBUQUERQUE, NEW MEXICO ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

TABLES<br />

Installation ID Installation<br />

Type<br />

(Nature/Extent)<br />

KAFB-10634,<br />

B<br />

KAFB-1063B,<br />

C<br />

KAFB-<br />

10613B, C<br />

KAFB-10637,<br />

B, C<br />

Horizontal and<br />

vertical extent of<br />

contaminants<br />

Vertical extent<br />

of contaminants<br />

Vertical extent<br />

of contaminants<br />

Nature of and<br />

vertical and<br />

horizontal extent<br />

of contaminants<br />

Co-<br />

Installations<br />

SVMW33<br />

SVMW30<br />

Groundwater<br />

Sampling<br />

(Depth)<br />

X<br />

X<br />

X<br />

X<br />

Rationale Horizon Contingency<br />

2x3" PVC wells in A and B<br />

horizon.<br />

Screen at 40' and 80'. Assess<br />

horiz and vertical gradient.<br />

Provide GW data in B,C<br />

horizon near VA well.<br />

Potentially assess vertical<br />

migration of dissolved plume.<br />

Screen at 40' and 80'. Assess<br />

horiz and vertical gradient.<br />

Provide GW data in B,C<br />

horizon near VA well.<br />

Potentially assess vertical<br />

migration of dissolved plume.<br />

2 boreholes. A Horiz: 4" inch<br />

across WT, Stainless screen.<br />

B/C Horiz: 3" PVC wells, 10'<br />

screens at 40 and 80.<br />

A, B<br />

B, C<br />

B, C<br />

A,B,C<br />

If concentrations exceed<br />

MCLs in the A- or B-<br />

horizons, additional<br />

assessment of the extent<br />

of gw contamination<br />

may be required to the E<br />

of this location. If<br />

concentrations exceed<br />

MCLs in the B-horizon<br />

only, additional<br />

assessment may be<br />

necessary for the C-<br />

horizon at this location.<br />

If gw from A-, B-, or C-<br />

horizon exceeds MCLs,<br />

will install additional<br />

wells within 750-ft. W<br />

of this location and will<br />

prepare for interim<br />

action at KAFB-15.<br />

If gw from A-, B-, or C-<br />

horizon exceeds MCLs,<br />

will install additional<br />

wells within 750-ft. W<br />

of this location. If C-<br />

horizon exceeds MCLs,<br />

will continue to assess<br />

vertical extent at this<br />

location.<br />

If the C-horizon exceeds<br />

any MCL, an assessment<br />

of the deeper<br />

groundwater at this<br />

Kirtland AFB<br />

Groundwater Investigation Work Plan BFF Table 3-3

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!