Appendix B—Case HistoriesLessons learnedThe incident demonstrated that although failures by hydraulic fracture may be mostcommon in first filling incidents, a potential for failures still exists years after the firstfilling. The soils were known to be highly dispersive, but designers thought that byplacing the dispersive soils above the elevation of the permanent pool, the threat tothe embankment dam could be reduced. <strong>Embankment</strong>s constructed of dispersiveclays are extremely susceptible to internal erosion failures unless protected bychimney filter zones.ReferenceOklahoma NRCS State Office files.B-107