4Command Line InterfaceExampleThis example sets the time out to 1000 seconds.Console(config)#interface ethernet 1/9Console(config-if)#sflow timeout 10000Console(config-if)#sflow destinationThis command configures the <strong>IP</strong> address and UDP port used by the Collector. Usethe no form to restore the default settings.Syntaxsflow destination ipv4 ip-address [destination-udp-port]no sflow destination• ip-address - <strong>IP</strong> address of the sFlow Collector.• destination-udp-port - The UDP port on which the Collector is listening forsFlow streams. (Range: 0-65534)Default Setting<strong>IP</strong> Address: nullUDP Port: 6343Command ModeInterface Configuration (Ethernet)ExampleThis example configures the Collector’s <strong>IP</strong> address, and uses the default UDP port.Console(config)#interface ethernet 1/9Console(config-if)#sflow destination ipv4 192.168.0.4Console(config-if)#sflow max-header-sizeThis command configures the maximum size of the sFlow datagram header. Use theno form to restore the default setting.Syntaxsflow max-header-size max-header-sizeno max-header-sizemax-header-size - The maximum size of the sFlow datagram header.(Range: 64-256 bytes)Default Setting128 bytesCommand ModeInterface Configuration (Ethernet)4-106