4Command Line Interfacelldp medFastStartCountThis command specifies the amount of MED Fast Start LLDPDUs to transmit duringthe activation process of the LLDP-MED Fast Start mechanism.Syntaxlldp medfaststartcount packetsseconds - Amount of packets. (Range: 1-10 packets; Default: 4 packets)Default Setting4 packetsCommand ModeGlobal ConfigurationCommand UsageThe MEDFastStartCount parameter is part of the timer which ensures that theLLDP-MED Fast Start mechanism is active for the port. LLDP-MED Fast Startis critical to the timely startup of LLDP, and therefore integral to the rapidavailability of Emergency Call Service.ExampleConsole(config)#lldp medfaststartcount 6Console(config)#lldp notification-intervalThis command configures the allowed interval for sending SNMP notifications aboutLLDP MIB changes. Use the no form to restore the default setting.Syntaxlldp notification-interval secondsno lldp notification-intervalseconds - Specifies the periodic interval at which SNMP notifications aresent. (Range: 5 - 3600 seconds)Default Setting5 secondsCommand ModeGlobal ConfigurationCommand Usage• This parameter only applies to SNMP applications which use data stored inthe LLDP MIB for network monitoring or management.• Information about changes in LLDP neighbors that occur between SNMPnotifications is not transmitted. Only state changes that exist at the time of a4-348