12.07.2015 Views

Management Guide - Kamery IP

Management Guide - Kamery IP

Management Guide - Kamery IP

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

3Configuring the SwitchConfiguring Event LoggingThe switch allows you to control the logging of error messages, including the type ofevents that are recorded in switch memory, logging to a remote System Log (syslog)server, and displays a list of recent event messages.System Log ConfigurationThe system allows you to enable or disable event logging, and specify which levelsare logged to RAM or flash memory.Severe error messages that are logged to flash memory are permanently stored inthe switch to assist in troubleshooting network problems. Up to 4096 log entries canbe stored in the flash memory, with the oldest entries being overwritten first when theavailable log memory (256 kilobytes) has been exceeded.The System Logs page allows you to configure and limit system messages that arelogged to flash or RAM memory. The default is for event levels 0 to 3 to be logged toflash and levels 0 to 7 to be logged to RAM.Command Attributes• System Log Status – Enables/disables the logging of debug or error messages tothe logging process. (Default: Enabled)• Flash Level – Limits log messages saved to the switch’s permanent flash memoryfor all levels up to the specified level. For example, if level 3 is specified, allmessages from level 0 to level 3 will be logged to flash. (Range: 0-7, Default: 3)Table 3-3 Logging LevelsLevel Severity Name Description7 Debug Debugging messages6 Informational Informational messages only5 Notice Normal but significant condition, such as cold start4 Warning Warning conditions (e.g., return false, unexpected return)3 Error Error conditions (e.g., invalid input, default used)2 Critical Critical conditions (e.g., memory allocation, or free memoryerror - resource exhausted)1 Alert Immediate action needed0 Emergency System unusable* There are only Level 2, 5 and 6 error messages for the current firmware release.• RAM Level – Limits log messages saved to the switch’s temporary RAM memoryfor all levels up to the specified level. For example, if level 7 is specified, allmessages from level 0 to level 7 will be logged to RAM. (Range: 0-7, Default: 7)Note: The Flash Level must be equal to or less than the RAM Level.3-36

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!