5. Electrical connections<br />
5.6 Controls<br />
Checking the motor protection switches<br />
The motor protection switch must be set for the appropriate<br />
rated current of the pumps – as described<br />
in Section 3 of this manual.<br />
5.7 Completion of electrical work<br />
After all electrical connection work has been completed in the<br />
control unit, the control unit cover must be closed and properly<br />
secured. In order to eliminate odour nuisances in the<br />
area where the control unit is installed, the conduit pipe to the<br />
control unit should be sealed with a special gaskets or simply<br />
with insulation foam.<br />
5.8 Control unit configuration (Models Jan 2010 and newer)<br />
The DIP switches are in the upper right portion of the control unit and have been set at the factory. Due to the explosion<br />
proof rating antiblocking mechanism has been switched off (switch 4) and must not be activated!<br />
1 2 3 4<br />
1. Switch: Sensor<br />
• Switch 1 up: Level measuring with float switches<br />
• Switch 1 down: Level measuring with pressure switch<br />
2. Switch: Level heights<br />
• Switch 2 up: Pumpstation (underground pumpstation)<br />
• Switch 2 down: Lifting station (floor mounted or dry mount inside chamber)<br />
3. Switch: This switch for customer service partners only<br />
4. Switch: Anti blocking function<br />
• Switch 4 up: anti blocking off<br />
• Switch 4 down: anti blocking on<br />
5.9 Control unit configuration (Models December 20<strong>09</strong> and older)<br />
The control unit configuration is set at the factory using switches S601 to S 604 which are between the levels switch connection<br />
jacks and the thermal protection inputs. These should be checked using the table below to make sure they are correct<br />
– the proper settings are marked in grey.<br />
– The four DIP switches (switch S604) are set at the factory and should not be changed.<br />
Models December<br />
20<strong>09</strong> and older<br />
S604 / 1<br />
S604 / 2<br />
S604 / 3<br />
S604 / 4<br />
ON<br />
running time control<br />
(lifting station)<br />
Submersible pump<br />
without OFF float switch<br />
Rotation / Phase controlled<br />
On<br />
Anti blocking function<br />
On<br />
OFF<br />
level controlled<br />
(submersible pump station)<br />
Submersible pump<br />
with OFF float switch<br />
Rotation / Phase controlled<br />
Off<br />
Anti blocking function<br />
Off<br />