8. Problems and Solutions<br />

Phase / rotation malfunction<br />

• Phase malfunction:<br />

--> Incorrect rotary field at power connection to control unit<br />

• Swap two phases<br />

Duo Pumpe 1/2<br />

• Phase L1, L2 or L3 not connected / live<br />

--> Check mains power connections to control unit, check power cable, check fuses<br />

--> If L1 is not live the rotary field error cannot be detected<br />

--> If L1 is not live the control unit goes into battery operation mode<br />

Max pump start protection<br />

Duo Pumpe 1<br />

• System has activated over 100,000 times which has caused a protection switch<br />

to activate<br />

--> Can be acknowledged by pressing the Alarm button – system will operate<br />

for an additional 1000 starts and then the warning will occur again<br />

--> Replace the protection switch – contact customer service<br />

Duo Pumpe 1<br />

Alarm level exceeded<br />

• Wastewater in pumpstation has reached the alarm level<br />

--> Audible alarm stops automatically if wastewater falls below alarm level<br />

--> LED warning goes out only after being acknowledged by pressing the Alarm button<br />

Relay malfunction<br />

• Power contactor / protector does not switch off<br />

--> Disconnect control unit from power source<br />

--> Replace the protection switch – contact customer service<br />

Duo Pumpe 1<br />

Duo Pumpe 2<br />