8. Problems and Solutions<br />
8.3.2 Motor Protection Switch<br />
In the case that a motor protection switch is activated either<br />
manually, by a short circuit or by an overload, a malfunction<br />
warning will be displayed and the malfunction relay will activate.<br />
8.3.3 Motor temperature<br />
Each motor of the Pumpstation Aqualift F is equipped with<br />
two temperature sensors which send data to the control unit.<br />
• Temperature (not recorded) – TF1a (TF2a)<br />
• Temperature (recorded) – TF1b (TF2b)<br />
In the case that temperature level TF1a has been reached it<br />
will be displayed on the control unit and the malfunction relay<br />
switch will activate. Also the control unit will shut down the<br />
pumps. As soon as the pumps cool down they will return to<br />
normal operation.<br />
In the case that temperature level TF1b has been reached it<br />
will be displayed on the control unit and the malfunction relay<br />
switch will activate. Also the control unit will shut down the<br />
pumps. As soon as the pumps cool down they will return to<br />
normal operation. The control unit will attempt to restart the<br />
pumps up to 30 times per every 2 minute period. The Temperature<br />
TF1b will not be stored in the control unit’s memory<br />
in the case of a power failure.<br />
In the case that the malfunction cannot be cleared, it is probable<br />
that the pump(s) are damaged and need to be replaced.<br />
Notice:<br />
In the case that the TF1b is exceeded and simultaneously the<br />
Alarm level is reached the following applies:<br />
• Press the Alarm button once will turn off the audible alarm<br />
• Press the Alarm button a second time to acknowledge the<br />
alarm (resets the alarm)<br />
8.4 Displayed Warnings<br />
Warnings will occur by:<br />
• the activation of the failure relay and the connected warning<br />
device.<br />
• display of the type of failure by LEDs on the control unit resulting<br />
From:<br />
Single pump units<br />
- Phase / rotation problems<br />
- Motor protection switch<br />
- Motor temperature<br />
- Running times / level<br />
- Relay error<br />
- Battery error<br />
- Power error<br />
- Level error<br />
- Maximum run time error<br />
- Maximum pump start/stop error<br />
Twin pump systems:<br />
- Phase / rotation problems<br />
- Motor protection switch<br />
- Motor temperature<br />
- Running times / level<br />
- Relay error<br />
- Battery error<br />
- Power error<br />
- Level error<br />
- Maximum run time error<br />
- Maximum pump start/stop error<br />
Conditions which can cause a warning to be displayed are<br />
individually listed in this manual<br />
8.5 ”Alarm” warnings<br />
Alarm warnings occur from:<br />
• the activation of the Alarm relay and the connected warning<br />
device<br />
• the internal signal sender<br />
Two situations can result in an alarm warning:<br />
1.The wastewater level inside the chamber rises above the<br />
level of the ”Alarm” float switch. The audible alarm can be<br />
turned off by pressing the ”Alarm” button. As soon as the<br />
wastewater has fallen below the ”Alarm” float level both<br />
alarms (signal and relay) will be cancelled.<br />
2. If a loaded battery is placed in the control unit, an audible<br />
alarm will be activated in the case of a power failure. This<br />
audible alarm will continue for several hours depending on<br />
the power in the battery. This alarm can be cancelled by<br />
pressing the ”Alarm” Reset button.<br />
8.6 What to do when…<br />
...The motor protection switch has activated -<br />
Open the control unit and reactivate the motor protection<br />
switch.<br />
...A different warning signal activates –<br />
in the case that a warning signal cannot be cleared by<br />
using the instructions in this manual, please contact a<br />
licensed electrician.<br />
...The Aqualift F no longer reacts to incoming signals -<br />
unplug the control unit of the Aqualift F for at least 10 seconds<br />
and then plug back in. In the case that the Aqualift<br />
no longer responds to incoming signal please contact a licensed<br />
professional<br />