Figure 29 Influence <strong>of</strong> combustor exit and primary zone temperature on the<br />

available amount <strong>of</strong> cooling air.<br />

Specific information on the use and performance <strong>of</strong> various extendedsurface<br />

configurations for the liners, including ribs, fins, and pedestals, may<br />

be found in Gardner [115] and Evans and Noble [116].<br />

One <strong>of</strong> the critical parameters that can limit application <strong>of</strong> these<br />

techniques is the pressure loss <strong>of</strong> the cooling system, which should not<br />

exceed 1.5–2% <strong>of</strong> the total compressor discharge pressure, otherwise causing<br />