Table 14. Storage server troubleshooting (continued)<br />

Problem<br />

indicator<br />

Component Possible cause Possible solutions<br />

One or more Expansion loop Drives are Ensure that the drives are<br />

green LEDs off<br />

improperly properly installed.<br />

(continued)<br />

installed or not<br />

installed<br />

Intermittent or<br />

sporadic power<br />

loss to the storage<br />

server<br />

Unable to access<br />

drives<br />

RAID controller<br />

has no power or<br />

has failed<br />

Impending drive<br />

failure<br />

Externally<br />

attached<br />

expansion port<br />

device has failed<br />

Some or all CRUs Defective ac<br />

power source or<br />

partially<br />

plugged-in power<br />

cord<br />

Drives and<br />

expansion loop<br />

Power supply<br />

has failed<br />

Midplane has<br />

failed<br />

Fibre-channel<br />

cabling has<br />

failed.<br />

RAID controller<br />

has failed<br />

Random errors Subsystem Midplane has<br />

failed<br />

72 IBM TotalStorage FAStT600 Fibre Channel Storage Server: Installation and User’s Guide<br />

Ensure that the unit is powered<br />

on. Replace the RAID controller.<br />

A bad drive or drives can issue<br />

LIPs that cause the drive<br />

expansion loop to go down<br />

momentarily. Use the RLS<br />

function in the<br />

storage-management software to<br />

determine which drives are bad.<br />

Replace the bad drives.<br />

Replace the expansion unit SFP<br />

or fibre-channel cable.<br />

Check the ac power source;<br />

verify that the ac circuit that the<br />

storage server connects to is not<br />

being overloaded. Reseat all<br />

installed power cables and power<br />

supplies. If applicable, check the<br />

power components. Replace<br />

defective power cords.<br />

Check for a Fault LED on the<br />

power supply, and replace the<br />

failed CRU.<br />

Have the midplane replaced<br />

(service technician only).<br />

Ensure that the fibre-channel<br />

cables are undamaged and<br />

properly connected.<br />

Replace the RAID controller.<br />

SFP has failed Ensure SFP is seated properly;<br />

replace SFP.<br />

Have the midplane replaced<br />

(service technician only).