Table 11. RAID controller LEDs (continued)<br />

Icon LED Color Operating states 1<br />

Expansion<br />

port bypass<br />

Expansion<br />

loop<br />

Amber v Off - Normal operation.<br />

v On - One of the following situations has<br />

occurred:<br />

– An SFP module is inserted in the drive<br />

loop port and the fibre-channel cable is<br />

not attached to it.<br />

– The fibre-channel cable is not attached<br />

to an expansion unit.<br />

– The attached expansion unit is not<br />

turned on.<br />

– An SFP has failed, a fibre-channel<br />

cable has failed, or an SFP has failed<br />

on the attached expansion unit.<br />

Green v On - Normal operation.<br />

v Off - The RAID controller circuitry has<br />

failed, or the RAID controller has no<br />

power.<br />

2Gbps 2Gbps Green v On - Normal operation (host connection is<br />

at 2Gbps).<br />

v Off - Host connection is at 1Gbps (which<br />

is not supported for controller firmware<br />

05.33.xx.xx.<br />

10BT 10BT Green v If the Ethernet connection is 10BASE-T:<br />

The 10BT LED is on, 100BT LED flashes<br />

faintly.<br />

v If the Ethernet connection is<br />

100BT 100BT<br />

100BASE-T: 10BT LED is off, 100BT LED<br />

is on.<br />

v If there is no Ethernet connection - Both<br />

LEDs are off.<br />

1 Always use the storage-management software to identify the failure.<br />

Fan fault LED<br />

Power supply<br />

Fan fault LED Power LED fault LEDs Power LED<br />

Figure 36. Fan and power supply LEDs<br />

42 IBM TotalStorage FAStT600 Fibre Channel Storage Server: Installation and User’s Guide