1. Follow the instructions in your expansion unit installation manual to set up and<br />

mount the new expansion unit.<br />

2. Use the following procedure and illustration to connect a single expansion unit<br />

to the storage server:<br />

a. Use a fiber-optic cable to connect to the FC-Expansion Units port on the left<br />

RAID controller in the storage server to the In port on the left ESM board of<br />

the expansion unit.<br />

b. Use a second fiber-optic cable to connect the FC-Expansion Units port on<br />

the right RAID controller in the storage server to the Out port on the right<br />

ESM board of the expansion unit.<br />

c. Ensure that the enclosure ID switch is set to a value different from one set<br />

for the FAStT600 server and other drive expansion enclosures in the loop.<br />

Also, ensure that the link speeds of the expansion units are set to 2 Gb.<br />

Left ESM board Right ESM board<br />

In port Out port<br />

Figure 32. Adding an expansion unit<br />

New expansion unit<br />

Storage server with<br />

two RAID controllers<br />

3. Remove the blank filler trays and insert drive trays. Connect power to the<br />

storage server, and then connect power to the drive expansion enclosures. After<br />

the enclosures are powered-on, the storage server locates the new drives.<br />

4. Use the storage-management software to check the status of the new drives,<br />

correct any errors found, and configure the new drives.<br />

Use the following procedure and illustration to connect a second expansion unit to<br />

the storage server after previously adding the first expansion unit:<br />

1. Ensure that the enclosure ID switch is set to a value different from one set for<br />

the FAStT600 server and other drive expansion enclosures in the loop. Also,<br />

ensure that the link speeds of the expansion units are set to 2 Gb.<br />

2. Disconnect cable ▌1▐ from its current connection and connect it to the In port on<br />

the left ESM board on the new expansion unit.<br />

3. Connect cable ▌2▐to the In port you disconnected in step 1 and the Out port on<br />

the left ESM board on the new expansion unit.<br />

4. Connect a third cable ▌3▐ to the In port on the right ESM board on the first<br />

expansion unit and the Out port on the right ESM board on the new expansion<br />

unit.<br />

32 IBM TotalStorage FAStT600 Fibre Channel Storage Server: Installation and User’s Guide

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!