Troubleshooting<br />

Always use the storage-management software to diagnose storage server problems<br />

and component failures. You can use Table 14 to find solutions to problems that<br />

have definite indicators.<br />

Table 14. Storage server troubleshooting<br />

Problem<br />

indicator<br />

Component Possible cause Possible solutions<br />

Amber LED on Drive CRU Drive failure Replace the drive that has failed.<br />

Fan CRU Fan failure Replace the fan that has failed.<br />

RAID controller RAID controller If the RAID controller Fault LED<br />

Fault LED failure<br />

is on, replace the RAID controller.<br />

Amber LED is off<br />

and green LED off<br />

Amber and green<br />

LEDs on<br />

Expansion or host<br />

port bypass LED<br />

If theRAID controller has been<br />

placed offline by the user, use<br />

storage management software to<br />

place it online. If the controller<br />

failed, replace the RAID<br />

controller.<br />

SFP port empty No corrective action is needed if<br />

this is a stand-alone storage<br />

server with no expansion units<br />

attached, and if the system is<br />

properly configured.<br />

Fibre-channel<br />

cable is not<br />

attached to the<br />

expansion unit<br />

The HBA, switch,<br />

or expansion<br />

units are set at<br />

1Gb/s<br />

No incoming<br />

signal detected<br />

Front panel General system<br />

error<br />

Power-supply<br />

CRU<br />

Power-supply<br />

CRU<br />

Power switch is<br />

turned off or ac<br />

power failure<br />

Power supply<br />

failure<br />

70 IBM TotalStorage FAStT600 Fibre Channel Storage Server: Installation and User’s Guide<br />

Otherwise, check to make sure<br />

that the drive expansion unit is<br />

powered on and the FC cables<br />

are attached properly.<br />

Connect the fibre-channel cable<br />

to the enclosure port; check other<br />

connections.<br />

The FAStT600 supports 2Gb/s<br />

fibre-channel connections only<br />

using the 05.33.xx.xx firmware.<br />

Make appropriate hardware<br />

changes to ensure the FAStT600<br />

ports are connecting to ports that<br />

operate at 2Gb/s.<br />

Reattach the SFPs and<br />

fibre-channel cables. Replace<br />

input and output SFPs or cables<br />

as necessary.<br />

Indicates that a Fault LED<br />

somewhere on the storage server<br />

has turned on. (Check for amber<br />

LEDs on CRUs.). Use Storage<br />

Manager software to diagnose<br />

server problems.<br />

Turn on all power-supply power<br />

switches.<br />

Replace the failed power-supply<br />

CRU.