Fault LED<br />

Fan CRU<br />

Latch<br />

Handle<br />

Figure 42. Fan locations<br />

Fan CRUs<br />

The two fan CRUs are hot-swappable and redundant.<br />

Fault LEDs<br />

These amber LEDs light when a fan failure occurs.<br />

Latches and handles<br />

Use the latches and handles to remove or install the fan CRUs.<br />

Attention: Do not run the storage server without adequate ventilation and cooling,<br />

because it might cause damage to the internal components and circuitry.<br />

Both fan units must always be in place, even if one is not functioning properly, to<br />

maintain proper cooling.<br />

Use the following procedure to replace a hot-swap fan:<br />

1. Check the LEDs on the back of the storage server.<br />

2. If the amber Fault LED is on, remove the fan CRU that has failed.<br />

a. Slide the latch to unlock the fan CRU.<br />

b. Use the handle (black knob) to pull the fan from the storage server. See<br />

Figure 43.<br />

Figure 43. Removing a fan<br />

3. Install the new fan unit.<br />

a. Place the fan CRU in front of the fan slot.<br />

54 IBM TotalStorage FAStT600 Fibre Channel Storage Server: Installation and User’s Guide<br />

Latch<br />

Handle<br />

Fan CRU<br />

Fault LED