. Hold the latch open, and slide the fan all the way into the slot. If the fan<br />

does not go into the bay, rotate it 180°. Ensure that the latch is on the side<br />

closest to the center of the storage server.<br />

c. Release the latch. If the lever remains open, pull back on the fan slightly,<br />

and then push it in again until the latch snaps into place.<br />

4. Check the LEDs.<br />

The Fault LEDs turn off after a few seconds. If they remain on, see<br />

“Troubleshooting” on page 70.<br />

Working with hot-swap power supplies<br />

The storage server power system consists of two power supply CRUs. The power<br />

supply CRUs provide power to the internal components by converting incoming ac<br />

voltage to dc voltage. One power supply CRU can maintain electrical power to the<br />

unit if the other power supply is turned off or malfunctions. The power supply CRUs<br />

are interchangeable (by reversing the locking levers).<br />

Each power supply CRU has a built-in sensor that detects the following conditions:<br />

v Over-voltage<br />

v Over-current<br />

v Overheated power supply<br />

If any of these conditions occurs, one or both power supplies will shut down. All<br />

power remains off until you cycle the power switches (turn the power switches off,<br />

wait at least 30 seconds, then turn the power switches on). For more information,<br />

see “Restoring power after an unexpected shutdown” on page 37 and “Restoring<br />

power after an over-temperature shutdown” on page 38.<br />

The power supplies are customer replaceable units (CRUs) and do not require<br />

preventive maintenance.<br />

v Always keep the power supplies in their proper places to maintain proper<br />

controller-unit cooling.<br />

v Use only the supported power supplies for your specific storage server.<br />

The power-supply controls on the rear of the storage server are shown in Figure 44<br />

on page 56.<br />

Chapter 5. Installing and replacing components 55